Release Notes
[Ref. #17359/13528] Audio monitoring: Audio playback is ~37 ms ahead of video, due to
an inherent processing limitation.
Workaround: It is possible to compensate for this delay using the audio monitoring delay
calibration introduced in version 3.00.
[Ref. #22910] Non-functional connection on Audio I/O TBA for the Kaleido-X16: The PC
In analog audio ports on the Kaleido-X16’s Audio I/O terminal block adapter (TBA) are
not functional in the current release of the Kaleido-X software.
Non-functional connections on Kaleido-X16: OPTION, PC In 1 Left, PC In 1 Right, PC In
2 Left, PC In 2 Right.
Non-functional connections on KXO-DUAL/KXO-DUAL3: OPTION 1, OPTION 2.
Non-functional buttons on Kaleido-RCP2: ALARM INHIBIT, SAVE.
Non-functional connections on KXI-DVI-Bridge: ETH 10/100.
Monitor Wall
[Ref. #KX-6287] Audio monitors: Although valid calibration values for out of phase
sensitivity are between -1 and 1, XEdit lets you set the threshold for an audio monitor’s
phase meter to a value that is outside of the valid range, after which audio monitors
may turn gray or unresponsive on the monitor wall.
Workaround: To recover from such a situation, set the phase meter threshold back to a
valid value (between -1 and 1) and then restart your multiviewer.
[Ref. #KX-4934/KX-6337] NV9000 source labels: In the case of a multiviewer with sources
from an upstream NV9000 router configuration, on rare occasions, after restarting the
multiviewer, UMDs may fail to show the expected source labels on the monitor wall.
Workaround: Refresh the layout on the monitor wall. If router source labels are still
missing after refreshing the layout, then restart the multiviewer.
[Ref. #KX-4907] Polish teletext: When WST teletext in Polish is displayed on the monitor
wall, accented characters may appear incorrectly.
[Ref. #KX-5861] Multi-program transport streams and Kaleido-IP: Kaleido-IP that
shipped with a version of the Kaleido-X software earlier than 6.30 may incorrectly
process multi-program transport stream (MPTS) sources where programs are added or
removed dynamically (e.g., when re-grooming or channel-lineup changes take place).
In such cases, it may happen that video and audio programs are shifted in the
Kaleido-IP sources table, resulting in incorrect video and audio on the monitor wall. If
you experience this problem after upgrading your system to version
6.30 or later,
please contact Technical Support for a solution (
Contact Us on page 59).
[Ref. #36618] Virtual alarms: Changing a virtual alarm’s name in XEdit may result in its
status becoming unavailable on the monitor wall.
Workaround: Refresh the layout on the monitor wall.
[Ref. #31880] Kaleido-X, Kaleido-X16 potential display issue: Occasionally, during a cold
start of the multiviewer, there could be a display corruption issue in the form of a
narrow strip of repeated content on the monitor wall.
Workaround: Restart the multiviewer.
[Ref. #13150] Closed captions: Closed captions may be fail to appear or they may be only
partially visible, when a monitor —
be it configured with transparency — overlaps the
area where the captions are expected to be displayed.