4. ELECTRICAL WIRING DIAGRAMS
Indoor units
MEES17K102
HBC controller
12
EIo-1
NOTE:1.TB02 is transmission terminal block.
Never connect power line to it.
2.The initial set values of switch on
Control Board are as follows.
SW1:0
SW2:0
LED1
SW1SW2
SWP2SWP1 SWP3
110
DSA001
(Blue)
(Yellow) (Green)
(Red)
(Green)
(Green)
(Blue)
(Blue)
(Blue)
(Yellow)
(Red)
(Red)
(Blue)
(Red) (Red)
(Red)
(Red)
(Red)
F001
250VAC
6.3A F
TO NEXT INDOOR UNIT
PULL BOX
FUSE(16A) BREAKER(16A)
POWER SUPPLY
~220V-240V
50Hz/60Hz
Indoor/outdoor
Transmission Line
t°
t°
t°
t°
t°
t°
t°
t°
t°
t°
t°
t°
t°
t°
t°
t°
t°
t°
t°
t°
t°
t°
t°
t°
t°
t°
M
M
M
UU
X002
X006
X003
ACL
SV1
21S4Mb 21S4Ma
ZNR001
L001
ZNR002
C004 C006
C003 C005
C002 C007
LEV1
LEV2
LEV3
WP1
WP2
1
3
1
7
2
6
3
5
4
4
5
3
6
2
1
2
32 1
7
1
2
1
1 1
1
1
1
11
1
1
2
22
2
2
3
33
3
3
2 2
2
2
3 3
3
3
4
4
11 24 45 56 6
PS1PS3
FS
Z
TH12
TH11
TH31c
TH31m
TH31b
TH31a
TH31f
TH31d
TH31n
TH13
TH31p
TH14
TH31o
TH31e
TH31h
TH31g
TH34
TH31i
TH31j
TH35
TH31k
TH31l
TH16
TH33
TH15
TH32
666
555
444
3
33222
111
Control Board
Power Board
1
1
1
1
1
11
1
3
1
1
1
1
2
2
2
2
2
22
2
1
2
2
2
2
3
3
3
3
3
33
3
3
3
3
3
4
4
4
4
4
55
4
4
4
4
4
5
5
5
5
5
77
5
5
5
6
6
6
6
6
7
7
99
6
6
5
3
1
1
355371
S(SHIELD)
TB02
M2
M1
CNLEV1 CNLEV2 CNLEV3
CN005
CNAC
CN002
CN001
CN001
CN002
CN006
CN203
CN204
CN401
CN103
CN101
CN518
CN507
CN512
CN515
CN516
CN513
CN514
CN201 CN003
CN101
CN003
CN501
CN502(Red)
CN504(Yellow)
CN506(Blue)
CN505
CN510
CN503(Blue)
CN508(Red)
CN509(Blue)
CN511(Red)
N
TB01
L
X
(Red)(Red) (Yellow)(Yellow) (Red) (Red) (Yellow) (Yellow) (Red) (Yellow)(Red) (Yellow)
MM MMMMMMMMMMM MMM
CN202
321
8765432
32145
CN201
1
4321321
87654321
CN203
5
CN204
4321321
87654321
54321321
87654321
CN205
5
CN206
443322113322115544332211332211554321321
87654321
54
321321
87654321
5
CN801
CN802(Red)
CN803(Yellow) CN806(Yellow)
CN805(Red)
CN804
CN207CN208
CN210 CN209 CN212 CN211
CN214 CN220CN213 CN219
CN216 CN218CN215 CN217
VB3k VB3a VB3bVB3l VB3cVB3m VB3dVB3n VB3eVB3o VB3fVB3p VB3g VB3jVB3h VB3i
Detail of X section
LD1:CPU in
operation
LD1:CPU in
operation
LD1:CPU in
operation
LD1:CPU in
operation
LD1:CPU in
operation
LD1:CPU in
operation
LD1:CPU in
operation
LD1:CPU in
operation
LD1:CPU in
operation
LD1:CPU in
operation
LD1:CPU in
operation
LD1:CPU in
operation
LD1:CPU in
operation
LD1:CPU in
operation
LD1:CPU in
operation
LD1:CPU in
operation
(Symbol explanation)
LEV1~3
TH11~16,TH32~35,
TH31a~p
ACL
PS1,PS3
Pressure sensor
Symbol
Name
AC reactor
Thermister sensor
Expansion valve
TB01
Terminal block
(for power source)
TB02
Terminal block
(for Transmission)
Fuse AC250V 6.3A F
F001
Solenoid valve
SV1
21S4Ma,21S4Mb
4 way valve
WP1,WP2
Pump
Name
Symbol
VB3a~p
Valve block
Z
FS
Function setting connector
Float switch
SW3
SW4
SW5
123456789
ON
123456789
ON
12345678
O
3.The wirings to TB01 and TB02 shown in
dotted line are field work.
10 10
CMB-WM1016V-AA
0000004671.BOOK 12 ページ 2018年3月13日 火曜日 午前11時9分