FX
3S
/FX
3G
/FX
3GC
/FX
3U
/FX
3UC
PLC User's Manual - Positioning Control Edition
Example Connection
Appendix 4. MELSERVO-J2 (-Super) Series
Appendix 4-3 Absolute Position Detection (Transistor Output)
Apx. - 39
A
Common Items
B
Built-in
Positioning
Functions
Apx.
Example
Connection
2. FX3G/FX3U PLC
*1. Be sure to use the class-D grounding method (grounding resistance: 100
or less).
*2. For details on the MR-J2(S) servo amplifier, such as the tolerance for the internal power and operation of the servo
amplifier, refer to the following manual.
For details, refer to the servo amplifier manual.
*3. Extension blocks are used in the connection example.
Inputs and outputs built into the main unit are available in place of extension blocks.
FX
3U
-32MT/ES
FX
3G
-40MT/ES
X000
24V
0V
S/S
N
L
100 to 240 V AC
COM1
FX
2N
-16EYT
Y020
Y027
Y021
Y022
Y023
SD
Plate
SON
ABSR
ABSM
SG
COM
CN1B
10
13
5
9
8
DO1
TLC
ZSP
4
6
19
S/S
X020
FX
2N
-16EX-ES/UL
X031
X032
X033
X037
VDD 3
*2
Photo-coupler
Photo-coupler
Class-D
grounding
*1
*3
*3
ABS (bit0)
ABS (bit1)
Servo-ON
ABS transfer mode
ABS request
Send data ready
MR-J2(S)A
Series servo
amplifier
Downloaded from ManualsNet.com search engine