EasyManua.ls Logo

Mitsubishi Electric MELSEC iQ-F Series - Page 18

Mitsubishi Electric MELSEC iQ-F Series
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16
3 SPECIFICATION
3.1 Details of the FB Library
Details of the input label array
*1 This indicates the array of the unused input label.
*2 When the individual automatic angle advance function is specified, set the angle advance amount so that it is 1 digit or more away from
the previous ON/OFF.
Array When the automatic angle advance is specified When the individual automatic angle advance is specified
Setting
point
Setting item Setting range Setting
point
Setting item Setting range
0 S0 Rotation speed a (rpm) 0 to 1000 rpm S0 Rotation speed a (rpm) 0 to 1000 rpm
1 ON angle advance
amount A (digit)
0 to resolution/2 ON angle advance
amount A (digit)
0 to resolution/2
Under the following condition
*2
2 S1 Rotation speed b (rpm) S0 rotation speed < S1 rotation
speed 1000 rpm
OFF angle advance
amount A (digit)
0 to resolution/2
Under the following condition
*2
3 ON angle advance
amount B (digit)
S0 ON angle advance amount <
S1 ON advance amount
resolution/2
S1 Rotation speed b (rpm) S0 rotation speed < S1 rotation
speed 1000 rpm
4 S2 Rotation speed c (rpm) S1 rotation speed < S2 rotation
speed 1000 rpm
ON angle advance
amount B (digit)
S0 ON angle advance amount <
S1 ON advance amount
resolution/2
Under the following condition
*2
5 ON angle advance
amount C (digit)
S1 ON angle advance amount <
S2 ON advance amount
resolution/2
OFF angle advance
amount B (digit)
S0 OFF angle advance amount <
S1 OFF advance amount
resolution/2
Under the following condition
*2

12 S6 Rotation speed g (rpm) S5 rotation speed < S6 rotation
speed 1000 rpm
S4 Rotation speed e (rpm) S3 rotation speed < S4 rotation
speed 1000 rpm
13 ON angle advance
amount G (digit)
S5 ON angle advance amount <
S6 ON advance amount
resolution/2
ON angle advance
amount E (digit)
S3 ON angle advance amount <
S4 ON advance amount
resolution/2
Under the following condition
*2
14
*1
*1
*1
OFF angle advance
amount E (digit)
S3 OFF angle advance amount <
S4 OFF advance amount
resolution/2
Under the following condition
*2
15 S5 Rotation speed f (rpm) S4 rotation speed < S5 rotation
speed 1000 rpm
16 ON angle advance
amount F (digit)
S4 ON angle advance amount <
S5 ON advance amount
resolution/2
Under the following condition
*2
17 OFF angle advance
amount F (digit)
S4 OFF angle advance amount <
S5 OFF advance amount
resolution/2
Under the following condition
*2
18 S6 Rotation speed g (rpm) S5 rotation speed < S6 rotation
speed 1000 rpm
19 ON angle advance
amount G (digit)
S5 ON angle advance amount <
S6 ON advance amount
resolution/2
Under the following condition
*2
20 OFF angle advance
amount G (digit)
S5 OFF angle advance amount <
S6 OFF advance amount
resolution/2
Under the following condition
*2
Y20
ON
angle
advance
amount
1 digit
or more
When the individual
automatic angle advance
function is not used
When the individual
automatic angle advance
function is used
0 degrees 359 degrees
1 digit
or more
1 digit
or more
ON
angle
advance
amount
OFF
angle advance
amount
OFF
angle advance
amount
Y20