Models
MS-CP13VA
-
GU1
MS-CP18VA
-
GU1
MS-CP24VA
-
GU1
MS-CP30VA
-
GU1
PARTS CATALOG (OBB782)
MS-CP13VA
HFC
utilized
R410A
INDOOR UNIT
SERVICE MANUAL
CONTENTS
1. TECHNICAL CHANGES ······························2
2. PART NAMES AND FUNCTIONS ··················3
3. SPECIFICATION ········································6
4. OUTLINES AND DIMENSIONS ·····················7
5. WIRING DIAGRAM ·····································9
6. REFRIGERANT SYSTEM DIAGRAM ··········· 10
7. SERVICE FUNCTIONS ······························ 12
8. MICROPROCESSOR CONTROL ················ 14
9. TROUBLESHOOTING ······························· 20
10. DISASSEMBLY INSTRUCTIONS ················· 41
Outdoor unit service manual
MU-CP∙VA Series (OBH783)
INDOOR UNIT
OBH782 is void.
Revision A:
• MS-CP30VA -
GU1
has been added.
No. OBH782
REVISED EDITION-A
TM

Questions and Answers

  • M
    Mario JohnsonAug 12, 2025
    How to fix a malfunctioning Mitsubishi Electric MS-CP13VA Air Conditioner remote?
    • A
      ahudsonAug 12, 2025
      If the remote controller for your Mitsubishi Electric Air Conditioner is malfunctioning, it might be due to weak batteries. Replacing the batteries should allow the remote controller to operate normally.
  • S
    Samantha CamposAug 18, 2025
    What does it mean if the upper lamp on my Mitsubishi Electric Air Conditioner blinks 4 times?
    • M
      mooredennisAug 18, 2025
      If the upper lamp on your Mitsubishi Electric Air Conditioner blinks 4 times, it indicates a problem with the indoor unit control system. The suggested solution is to replace the indoor electronic control P.C. board.
  • K
    kimberlynicholsAug 27, 2025
    What does it mean if the upper lamp on my Mitsubishi Electric MS-CP13VA blinks twice?
    • S
      Sherri CohenAug 27, 2025
      If the upper lamp on your Mitsubishi Electric Air Conditioner blinks 2 times, it indicates a trouble with the room temperature or indoor coil thermistor. You should check the room temperature thermistor and the indoor coil thermistor.
  • B
    Brandon CrosbySep 3, 2025
    What does it mean if the upper lamp on my Mitsubishi Electric Air Conditioner blinks 3 times?
    • M
      Martin GarrisonSep 3, 2025
      If the upper lamp on your Mitsubishi Electric Air Conditioner blinks 3 times, this indicates a problem with the indoor fan motor.

Mitsubishi Electric MS-CP13VA Specifications

General IconGeneral
BrandMitsubishi Electric
ModelMS-CP13VA
CategoryAir Conditioner
LanguageEnglish