EasyManua.ls Logo

Mitsubishi Electric MS09EW User Manual

Mitsubishi Electric MS09EW
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SERVICE
&
PARTS
MANUAL
Wireless type
Models
INDOOR UNlT
MSOSEW
MS12EN
OUTDOOR UNlT
Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric MS09EW and is the answer not in the manual?

Mitsubishi Electric MS09EW Specifications

General IconGeneral
Cooling Capacity2.5 kW
Heating Capacity3.2 kW
RefrigerantR32
Power Supply220-240 V, 50 Hz
Noise Level (Indoor Unit)21 dB
Noise Level (Outdoor Unit)49 dB(A)

Summary

CHANGE POINTS

FEATURES

NEW "I FEEL CONTROL" IN OUR LCD WIRELESS REMOTE CONTROLLER

Describes a new remote control feature with advanced functions and user-friendly interface.

A VARIETY OF MICROPROCESSOR-CONTROLLED FUNCTION

Lists various microprocessor-controlled functions like Auto Stop, Auto Fan Speed, and Restart.

SPECIFICATIONS

DATA

PERFORMANCE CURVE

Shows performance curves relating capacity and power consumption to operating conditions.

CONDENSING PRESSURE AND SUCTION PRESSURE

Presents charts for condensing and suction pressures based on ambient and indoor temperatures.

MAX. REFRIGERANT PIPING LENGTH & MAX. HEIGHT DIFFERENCE

Illustrates maximum refrigerant piping lengths and height differences for different unit configurations.

STANDARD OPERATION DATA

Provides standard operating data for various models under different conditions.

OUTLINES AND DIMENSIONS

WIRING DIAGRAM

REFRIGERANT SYSTEM DIAGRAM

MICROPROCESSOR CONTROL

"I FEEL CONTROL" OPERATION

Details the operation of the "I FEEL CONTROL" feature using the remote controller.

COOL OPERATION

Explains the steps to perform a standard COOL operation.

DRY OPERATION

Details the procedure for operating the unit in DRY mode.

FAN OPERATION

Describes how to operate the unit in FAN-only mode and fan speed settings.

TIMER

Explains the AUTO STOP and AUTO START timer functions.

EMERGENCY-TEST OPERATION

Details the emergency operation mode for testing or when the remote is unavailable.

SERVICE FUNCTION

AUTO RESTART FUNCTION

Explains how the unit automatically restarts after a power failure.

HOW TO RECONSTRUCT FOR INDIVIDUAL OPERATION

Covers the procedure for setting up multiple units with one remote controller.

TROUBLE SHOOTING

SELF CHECK FUNCTION

Describes the self-check function to identify defects via indicator lights.

OPERATION DOES NOT START

Provides a flowchart for troubleshooting when the unit fails to start.

COMPRESSOR AND OUTDOOR FAN DO NOT OPERATE

Offers a troubleshooting guide for situations where fans operate but compressor does not.

RELAY OPERATION

Details relay operations for different modes and fan speeds.

OPTIONAL PARTS

REFRIGERANT PIPES

Lists optional extension pipes, their part numbers, lengths, and specifications.

STANDARD PARTS

INDOOR UNIT PARTS MS09EW

Shows an exploded view and parts list for the MS09EW indoor unit.

OUTDOOR UNIT PARTS MU09EW

Shows an exploded view and parts list for the MU09EW outdoor unit.

OUTDOOR UNIT PARTS MUM18EW

Details the parts for the MUM18EW outdoor unit, referencing the indoor unit section.

INDOOR UNITS PARTS MS12EN MS15EN

Provides an exploded view and parts list for MS12EN and MS15EN indoor units.

OUTDOOR UNIT PARTS MU12EN MU15EN

Lists the parts for MU12EN and MU15EN outdoor units.

ACCESSARY & REMOTE CONTROLLER PARTS

Lists accessory and remote controller parts for various models.

Related product manuals