8 FUNCTIONS
8.9 Firmware Update Function
Setting procedure
To perform a firmware update on the I/O module, the CC-Link IE TSN Firmware Update Tool must be set.
For details on the CC-Link IE TSN Firmware Update Tool, refer to the "Help".
Setting the Network Configuration Settings window
Set the following items in the Network Configuration Settings window.
When CCIET_DIO is used for "Module Name", CCIET_DIO is automatically set for "FTP User name" and
"FTP Password".
When the firmware update file to be used is the same, and the strings of the module names set in the CC-
Link IE TSN Firmware Update Tool also match (the model names of the actual devices can differ), a
firmware update can be performed on I/O modules with different model names simultaneously.
Example: All the module names of the firmware update target I/O modules are set to NZ2GN2B1.
Item Setting details
Module Name Set the model names of the firmware update target I/O modules.
IP Address Set the IP addresses of the firmware update target I/O modules.
Equipment Name This setting is optional.
Set this item when you register multiple pieces of equipment and need to distinguish them.
FTP User name Set CCIET_DIO in this column.
FTP Password Set CCIET_DIO in this column.