APPX
Appendix 1 Remote I/O Signal
217
A
APPENDICES
Appendix 1 Remote I/O Signal
List of remote I/O signals
I/O signals for a master/local module are listed as follows.
The I/O signals in this section are the examples with the start of remote I/O signals of the I/O module assigned to the device
number of RX0 and RY0.
Remote input (RX) indicates the input signal from the I/O module to the master/local module.
Remote output (RY) indicates the output signal from the master/local module to the I/O module.
Do not use any "Use prohibited" remote I/O signals. Doing so may result in an accident due to an incorrect
output or malfunction.
Input module (16-point module)
■Remote input signal
■Remote output signal
Device number Name
RX0 External input signal X0
RX1 External input signal X1
RX2 External input signal X2
RX3 External input signal X3
RX4 External input signal X4
RX5 External input signal X5
RX6 External input signal X6
RX7 External input signal X7
RX8 External input signal X8
RX9 External input signal X9
RXA External input signal XA
RXB External input signal XB
RXC External input signal XC
RXD External input signal XD
RXE External input signal XE
RXF External input signal XF
Device number Name
RY0 to RYF Use prohibited