I/O Module Type Building Block
User's Manual
QX10 QY10
QX10-TS QY10-TS
QX28 QY18A
QX40 QY22
QX40-S1 QY40P
QX40-TS QY40P-TS
QX40H QY41H
QX41 QY41P
QX41-S1 QY42P
QX41-S2 QY50
QX42 QY68A
QX42-S1 QY70
QX50 QY71
QX70 QY80
QX70H QY80-TS
QX71 QY81P
QX72 QY82P
QX80 QH42P
QX80-TS QX41Y41P
QX80H QX48Y57
QX81 QI60
QX81-S2
QX82
QX82-S1
QX90H

Table of Contents

Questions and Answers

  • S
    Shannon MorrisAug 22, 2025
    What to do if an input signal does not turn off on my Mitsubishi Electric QX80?
    • K
      Kevin EllisAug 22, 2025
      If an input signal on your Mitsubishi Electric Controller doesn't turn off, it could be due to a few reasons. One cause may be leakage current from the input switch. To resolve this, connect an appropriate resistor to ensure the voltage across the input module terminals is less than the off voltage. A CR constant of 0.1 to 0.47 F + 47 to 120? (1/2W) is recommended. Another cause could be driving the system with a limit switch that has a neon lamp. The solution is the same as above, or you could create an independent display circuit. Lastly, leakage current from the wiring cable's line capacity could be the problem. The solution is the same as the first example; however, leakage current is not generated when the power supply is located in the input equipment side.
  • M
    murphyandreaNov 5, 2025
    What to do if Mitsubishi Electric QX80 Controller input signal does not turn OFF?
    • K
      Kelly RoseNov 5, 2025
      If the input signal of your Mitsubishi Electric Controller doesn't turn OFF, several factors could be the cause. Here are some potential solutions: * If the issue is due to leakage current from the input switch, connect an appropriate resistor to lower the voltage across the input module terminals below the OFF voltage value. A CR constant of 0.1 to 47 F + 47 to 120 (1/2W) is recommended. * If it's due to a limit switch with a neon lamp, apply the same solution as above or create an independent display circuit. * For leakage current from the wiring cable's line capacity, use the same resistor solution. Note that leakage current isn't generated when the power supply is on the input equipment side. * If using a switch with an LED indicator, connect a resistor to lower the voltage be...

Summary

Mitsubishi Electric MELSEC-Q Safety Precautions

Design Precautions for MELSEC-Q Modules

Configure safety circuits and handle controller faults to ensure safe operation.

Installation Precautions for I;O Modules

Guidelines for safely mounting and installing I/O modules on the base unit.

Wiring Precautions for MELSEC-Q

Safe and correct wiring practices for connecting modules to external devices.

Startup and Maintenance Precautions

Procedures for safely starting up and maintaining I/O modules.

MELSEC-Q Product Conditions of Use

1. General Specifications and Precautions for MELSEC-Q

1.2 Precautions for MELSEC-Q I;O Module Use

Provides essential precautions for using input and output modules correctly.

1.2 Precautions for MELSEC-Q I;O Module Use

1.2.1 Input Module Precautions

Details precautions for using input modules, including simultaneous ON points and response time.

1.2.2 Output Module Precautions

Precautions for output modules, including switching frequency, load connection, and fuse replacement.

1.2.6 Module Installation and Wiring Guidelines

Provides guidelines for installing and wiring modules, including wire size and torque.

1.3 MELSEC-Q I;O Module Settings

1.3.1 Setting I;O Response Time

Describes how to set the I/O response time using GX Developer software.

2. MELSEC-Q Input Module Specifications

2.1 QX10 AC Input Module Specifications

Provides specifications, derating chart, and external connections for the QX10 AC input module.

2.2 QX10-TS AC Input Module Specifications

Details specifications and external connections for the QX10-TS AC input module.

2.3 QX28 AC Input Module Specifications

Lists specifications, derating chart, and external connections for the QX28 AC input module.

2.4 QX40 DC Input Module (Positive Common Type)

Specifications and external connections for the QX40 DC input module.

2.5 QX40-S1 DC Input Module (Positive Common Type)

Details specifications, response time, and external connections for QX40-S1 DC input module.

2.6 QX40-TS DC Input Module (Positive Common Type)

Specifications and external connections for the QX40-TS DC input module.

2.7 QX40 H DC High-Speed Input Module (Positive Common Type)

Specifications for high-speed input module, including noise filter and function settings.

2.8 QX41 DC Input Module (Positive Common Type)

Specifications and pin-outs for the QX41 DC input module.

2.9 QX41-S1 DC Input Module (Positive Common Type)

Details specifications and response times for the QX41-S1 DC input module.

2.15 QX70 H DC High-speed Input Module (Positive Common Type)

Specifications for high-speed input module, including noise filter and function settings.

2.20 QX80 H DC High-speed Input Module (Negative Common Type)

Specifications for high-speed input module, including noise filter and function settings.

3. MELSEC-Q Output Module Specifications

3.7 QY41 H Transistor High-speed Output Module (Sink Type)

Specifications for QY41H high-speed transistor output module (sink type).

4. MELSEC-Q I;O Combined Module

5. MELSEC-Q Interrupt Module

9. MELSEC-Q Spring Clamp Terminal Block

11. MELSEC-Q I;O Module Troubleshooting

11.1 Input Circuit Troubleshooting

Describes common input circuit problems and their corrective actions.

11.2 Output Circuit Troubleshooting

Explains common output circuit problems and their corrective actions.