12 DATA USED FOR POSITIONING CONTROL
12.2 List of Buffer Memory Addresses
395
12
Block start data
n: Axis No. - 1
Positioning data No.2 6010+1000n
6019+1000n
71010+1000n
71011+1000n
No.3 6020+1000n
6029+1000n
71020+1000n
71021+1000n
No.100 6990+1000n
6999+1000n
71990+1000n
71991+1000n
No.101 Set with the engineering tool.
No.600
Memory area Item Buffer memory address
Positioning
data (Starting
block data)
Starting
block 0
Block start data 1st
point
[Da.11]
[Da.12]
Shape
Start data No.
22000+400n
[Da.13]
[Da.14]
Special start instruction
Parameter
22050+400n
Starting block 0 2nd point 22001+400n 22051+400n
3rd point 22002+400n 22052+400n

50th point 22049+400n 22099+400n
Starting
block 0
Condition data
No.1
[Da.15] Condition target 22100+400n
[Da.16] Condition operator
[Da.17] Address 22102+400n
22103+400n
[Da.18] Parameter 1 22104+400n
22105+400n
[Da.19] Parameter 2 22106+400n
22107+400n
[Da.23] Number of simultaneously
starting axes
Simultaneously
starting axis
22108+400n
22109+400n
[Da.24] Simultaneously starting axis
No.1
[Da.25] Simultaneously starting axis
No.2
[Da.26] Simultaneously starting axis
No.3
Starting block 0 Condition data No.2 22110+400n
22119+400n
Condition data No.3 22120+400n
22129+400n

Condition data No.10 22190+400n
22199+400n
Memory area Item Buffer memory address