SPLIT-SYSTEM HEAT PUMP
SLZ-KF09, KF12, KF15, KF18NA
English
INSTALLATION MANUAL
For safe and correct use, please read this manual and the outdoor unit installation manual thoroughly before
installing the air-conditioner unit.
FOR INSTALLER
Español
MANUAL DE INSTALACIÓN
Para un uso seguro y correcto, lea detalladamente este manual de instalación antes de montar la unidad de
aire acondicionado.
PARA EL INSTALADOR
Français
MANUEL D’INSTALLATION
Avant d’installer le climatiseur, lire attentivement ce manuel, ainsi que le manuel d’installation de l’appareil
extérieur pour une utilisation sûre et correct.
POUR L’INSTALLATEUR

Questions and Answers:

Mitsubishi Electric SLZ-KF09 Specifications

General IconGeneral
SeriesSLZ-KF
Cooling Capacity2.5 kW
Heating Capacity3.2 kW
RefrigerantR410A
Indoor Unit Dimensions (W x H x D)800 x 270 x 300 mm
Outdoor Unit Dimensions (W x H x D)800 x 550 x 300 mm
Seasonal Energy Efficiency Ratio (SEER)6.10
SEER6.10
Heating Seasonal Performance Factor (HSPF)3.80
HSPF3.80
Indoor Unit Weight9.5 kg
Outdoor Unit Weight34 kg
Indoor Unit Noise Level32 dB(A)
Power Supply220-240V / 50Hz

Summary

Safety Precautions and Installation Location

General Safety Warnings

Consolidates all critical safety warnings, cautions, and essential precautions for safe operation and installation.

Grounding and Electrical Safety Guidelines

Details essential procedures for proper grounding and electrical safety during installation to prevent hazards.

Indoor Unit Placement Guidelines

Specifies optimal locations for indoor unit installation, considering airflow and environmental factors.

Wireless Remote Controller Mounting

Provides instructions for mounting the wireless remote controller for optimal signal reception and usability.

Installation Diagram and Indoor Unit Mounting

Indoor Unit Installation Diagram

Illustrates the installation layout and dimensions for the indoor unit, including clearance requirements.

Outdoor Unit Installation Reference

Directs users to the outdoor unit installation manual for specific outdoor unit setup procedures.

Indoor Unit Accessories Check

Lists and describes the accessories supplied with the indoor unit for installation purposes.

Ceiling Opening & Suspension Bolt Installation

Details the process for creating ceiling openings and installing suspension bolts for the indoor unit.

Indoor Unit Mounting Procedures

Duct Installation for Fresh Air Intake

Instructions for installing the duct and flange for fresh air intake connections to the indoor unit.

Suspension Structure and Unit Mounting

Guidance on reinforcing the ceiling structure and procedures for suspending the main indoor unit.

Confirming Unit Position and Tightening Bolts

Steps to align the indoor unit correctly and securely tighten suspension bolts.

Refrigerant Piping Work Details

Refrigerant Piping Safety Precautions

Key safety measures and precautions to be observed when working with R410A refrigerant.

Refrigerant Pipe Specifications

Details the specifications for commercially available copper pipes, including diameter and wall thickness.

Flaring Work Procedures and Checks

Step-by-step guide for performing flaring work on refrigerant pipes to prevent leakage.

Refrigerant Pipe Connection Procedures

Piping Locations and Dimensions

Illustrates refrigerant and drainage piping locations and provides dimensional data for various models.

Connecting Indoor and Outdoor Unit Pipes

Instructions for connecting refrigerant pipes, including oil application, tightening, and leak checks.

Drainage Piping Work Procedures

Drainage Piping Installation and Checks

Guidelines for installing the drain pipe, ensuring proper slope, connections, and checking for smooth flow.

Electrical Work: Power and Wiring

Indoor Unit Power Supply Configurations

Details wiring patterns for indoor unit power supply from the outdoor unit, including circuit ratings.

Indoor Unit Electrical Connection Steps

Step-by-step instructions for connecting power supply and indoor/outdoor unit connecting cables.

Electrical Work: Sensors and Receivers

Installing i-See Sensor and Signal Receiver

Instructions for connecting and installing i-See sensor and signal receiver components within the grille assembly.

Electrical Work: Remote Controller Setup

Wired Remote Controller Installation Guide

Reference to installation procedures for wired remote controllers included with the system.

Wireless Remote Controller Installation

Guidance on selecting the installation area and mounting the wireless remote controller.

Wireless Remote Controller Initial Settings

Procedures for setting initial parameters such as clock, temperature unit, and time display.

Electrical Work: Function Settings

Wired Remote Controller Function Settings

Steps to access and configure function settings for indoor units using a wired remote controller.

Wireless Remote Controller Function Settings

Process for selecting and setting various functions like unit number and mode via wireless remote controller.

Electrical Work: Airflow Direction Control

Setting Fixed Up/Down Airflow Direction

Instructions on how to fix the up/down airflow direction for specific outlets, overriding remote control settings.

Manual Vane Angle Adjustment Procedure

Test Run and Pre-Checks

Pre-Test Run Installation Checks

Essential checks to perform before initiating the test run, including wiring and refrigerant leakage.

Wired Remote Controller Test Run

Procedure for performing a test run using the wired remote controller to verify unit operation.

Test Run Operation and Error Handling

Test Run Error Codes and Symptoms

Lists common error codes, symptoms, and their causes detected during the test run operation.

Wireless Remote Controller Test Run

Steps for conducting a test run using the wireless remote controller, including mode activation.

Self-Check and Drainage Verification

Procedures for performing self-checks and verifying proper drainage operation after installation.

System Control and Grille Installation

System Control Overview

Brief reference to the outdoor unit installation manual for system control information.

Grille Accessory Check List

Lists all accessories included with the grille for installation, ensuring all parts are present.

Grille Installation: Preparation and Mounting

Ceiling Opening and Grille Preparation

Ensures correct ceiling opening dimensions and prepares the grille for attachment.

Removing Intake Grille and Corner Panel

Instructions for safely removing the intake grille and corner panel for access.

Temporary and Secure Grille Attachment

Guides on temporarily hanging and then securely fastening the grille to the main unit.

Grille Installation: Wiring Connections

Connecting Vane Motor and Panel Wires

Details how to connect the vane motor and panel vane motor wires correctly in the connector box.

Wiring i-See Sensor and Signal Receiver

Instructions for routing and connecting wires for the i-See sensor and signal receiver.

Grille Installation: Final Steps

Locking Up/Down Airflow Direction

Procedure to lock the up/down airflow direction of the vanes, disabling remote control operation.

Installing Intake Grille and Final Checks

Reverse procedure for installing the intake grille and performing final checks on gaps and connections.