EasyManua.ls Logo

Mitsubishi Electric SU-2.5VR User Manual

Mitsubishi Electric SU-2.5VR
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
TECHNICAL & SERVICE MANUAL
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
SPLIT-TYPE, AIR CONDITIONERS
CONTENTS
1. TECHNICAL CHANGES ···········································2
2. COMBINATION OF INDOOR OUTDOOR UNITS·····2
3. PART NAMES AND FUNCTIONS·····························3
4. SPECIFICATIONS ·····················································4
5. DATA··········································································7
6. OUTLINES AND DIMENSIONS ······························10
7. WIRING DIAGRAM ·················································13
8.
REFRIGERANT SYSTEM DIAGRAM
···························19
9. TROUBLESHOOTING ············································28
10. DISASSEMBLY PROCEDURE ·······························32
11. PARTS LIST ····························································48
No. OC282
REVISED EDITION-B
OUTDOOR UNIT
Outdoor unit
[Model names] [Service Ref.]
SUH-1VR SUH-1VR.TH
SUH-1.6VR SUH-1.6VR.TH
SUH-1.6VR2 SUH-1.6VR2.TH
SUH-2VR SUH-2VR.TH SUH-2VR
1
.TH SUH-2VR
2
.TH
SUH-2.5VR SUH-2.5VR.TH
SU-1.6NR SU-1.6NR.TH
SU-2NR SU-2NR.TH
SU-2.5NR SU-2.5NR.TH
SU-1VR SU-1VR.TH SU-1VR.TH-T
SU-1.6VR SU-1.6VR.TH SU-1.6VR.TH-T
SU-1.6VR2 SU-1.6VR2.TH SU-1.6VR2.TH-T
SU-2VR SU-2VR.TH SU-2VR.TH-T
SU-2VR
1
.TH SU-2VR
1
.TH-T
SU-2.5VR SU-2.5VR.TH SU-2.5VR.TH-T
• SU-1VR.TH-T, SU-1.6VR2.TH-T and SU-2VR1.TH-T
has been added.
• Instruction of troubleshooting has been added to
pege 29 ans 30.
• Please void OC282 REVISED EDITION-A.
OC282-A--1.qxp 03.1.28 4:29 PM Page 1
Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric SU-2.5VR and is the answer not in the manual?

Mitsubishi Electric SU-2.5VR Specifications

General IconGeneral
TypeSplit System
Cooling Capacity2.5 kW
Heating Capacity3.2 kW
Power Supply220-240V, 50Hz
Indoor Unit Weight9.5 kg

Summary

Technical Changes

Combination of Indoor/Outdoor Units

Part Names and Functions

Specifications

Data

Outlines and Dimensions

Wiring Diagram

Refrigerant System Diagram

Max. Refrigerant Piping Length & Max. Height Difference

Additional Refrigerant Charge (R-22 : g)

Evacuation Procedures

Troubleshooting

Test Point of P.C. Board

Details test points on the deicer P.C. board for diagnosing issues.

Trouble Criterion of Main Parts

Provides resistance checks and criteria for key components like compressor and fan motor.

Disassembly Procedure

Parts List