SERVICE MANUAL
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
CONTENTS
1.
COMBINATION OF INDOOR AND OUTDOOR UNITS
...
2
2. PART NAMES AND FUNCTIONS
......................
2
3. SPECIFICATION
.................................................
3
4. OUTLINES AND DIMENSIONS
..........................
4
5. WIRING DIAGRAM
............................................
5
6. REFRIGERANT SYSTEM DIAGRAM
................
9
7. DATA
.................................................................
10
8. ACTUATOR CONTROL
....................................
12
9. SERVICE FUNCTION
.......................................
13
10. TROUBLESHOOTING
......................................
13
11. FUNCTION SETTING
.......................................
29
12. DISASSEMBLY INSTRUCTIONS
.....................
32
HFC
utilized
R410A
R410A
Note:
This service manual describes
service data of the outdoor units
only.
PARTS CATALOG (OCB699)
No. OCH699
December 2018
Outdoor unit
[Model Name]
SUZ-KA09NA2
SUZ-KA09NAH2
SUZ-KA12NA2
SUZ-KA12NAH2
SUZ-KA15NA2
SUZ-KA15NAH2
[Service Ref.]
SUZ-KA09NA2.MX
SUZ-KA09NAH2.MX
SUZ-KA12NA2.MX
SUZ-KA12NAH2.MX
SUZ-KA15NA2.MX
SUZ-KA15NAH2.MX
SUZ-KA09NA(H)2.MX
Air outlet
Drain outlet
Piping
Drain hose
Air inlet
(back and side)

Questions and Answers:

Mitsubishi Electric SUZ-KA12NAH2.MX Specifications

General IconGeneral
BrandMitsubishi Electric
ModelSUZ-KA12NAH2.MX
CategoryAir Conditioner
LanguageEnglish

Summary

9 SERVICE FUNCTION

10 TROUBLESHOOTING

10-1. CAUTIONS ON TROUBLESHOOTING

Important precautions before and during troubleshooting procedures.

10-2. TROUBLE SHOOTING CHECK TABLE

10-3. HOW TO PROCEED "SELF-DIAGNOSIS"

10-3-1. Self-diagnosis <PAR-3xMAA ("x" represents 0 or later)>

Procedure for using the self-diagnosis function via wired remote controller.

10-4. TROUBLE CRITERION OF MAIN PARTS

10-5. TROUBLESHOOTING FLOW

A How to check inverter/compressor

Steps to check the inverter and compressor for issues.

B Check of open phase

Procedure to check for open phase in the inverter output.

D Check of compressor winding

Method to check the resistance of compressor windings.

E Check of compressor operation time

How to measure compressor operation time for overcurrent detection.

F Check of compressor start failure

Procedure to diagnose compressor start failure.

G Check of outdoor thermistors

Procedure to check the resistance of outdoor thermistors.

Check of inverter P.C. board

11 FUNCTION SETTING

11-1. Selecting functions using the wired remote controller <PAR-3xMAA ("x" represents 0 or later)>

12 DISASSEMBLY INSTRUCTIONS

Related product manuals