5 - 115
MELSEC-A
5 DATA USED FOR POSITIONING CONTROL
Storage buffer
memory address
Setting value Default value
Axis 1 Axis 2 Axis 3
0
1154
1155
1204
1205
1254
1255
Set with a decimal.
R
×
10
n
Unit conversion table
)
)
Cd.15
Example)
n
1
mm
5
inch
5
degree
0
pulse
Unit
n
2
mm/min
3
inch/min
3
degree/min
0
pulse/s
Unit
Actual
value
Integer value
Unit conversion table
)
)
Cd.16
Setting value
(decimal)
When setting "10000.00mm/min" in the
" New speed value", set "1000000"
in the buffer memory.
Cd.16
Cd.15
New current value
Cd.16
New speed value
0
1156
1157
1206
1207
1256
1257
Set with a decimal.
K
1
Setting value
After accepting the speed change, "0" is stored by the OS.
(Indicates that the speed change acceptance is completed.)
Cd.17
Speed change request
1: Change speed
(Set by sequence program)
0 1158 1208 1258
Set with a decimal.
K
Override value (%)
1 to 300
Setting value
0 1159 1209 1259