PURY-HP-T(S)KMU,-Y(S)KMU (September 2014)
H2i-R2-19
© 2014 Mitsubishi Electric US, Inc.
4. ELECTRICAL WIRING DIAGRAMS
4. ELECTRICAL WIRING DIAGRAMS
DATA U10
OUTDOOR UNITS 2 - 260
H2i R2
PURY-HP72, 96YKMU-A(-BS)
For opening/closing the bypass
circuit
Terminal
block
Central control transmission
cable
Indoor/Outdoor transmission
cable
Power supply
Function setting connector
IPM temperature
OA temperature
ACC inlet pipe temperature
Discharge pipe temperatureThermistor
SV9
TB1
TB3
TB7
TH4
TH5
TH6
TH7
THHS
Z24,25
DC reactor
Current sensor(AC)
Magnetic relay(inverter main circuit)
Low pressure
Discharge pressure
High pressure protection for
the outdoor unit
Pressure
switch
Pressure
sensor
Explanation
4-way valve(Cooling/Heating switching)
For opening/closing the bypass
circuit under the O/S
Solenoid
valve
DCL
LEV5a
CT12,22,3
72C
63LS
63HS1
63H1
<Symbol explanation>
Symbol
21S4a
SV1a
SV5b Outdoor unit heat exchanger
capacity control
Subcooled liquid refrigerant
temperature
*1. Single-dotted lines indicate wiring not supplied
with the unit.
*2. Dot-dash lines indicate the control box boundaries.
*3. Refer to the Data book for connecting input/output
signal connectors.
*4. Daisy-chain terminals (TB3) on the outdoor units in the
same refrigerant system together.
*5. Faston terminals have a locking function.
Make sure the terminals are securely locked in place
after insertion. Press the tab on the terminals to
removed them.
*6. Control box houses high-voltage parts.
Before inspecting the inside of the control box,turn off
the power,keep the unit off for at least 10 minutes, and
confirm that the voltage between FT-P and FT-N on
INV Board has dropped to DC20V or less.
For inrush current preventionResistorR1,5
Heat exchanger capacity controlSV4a,b,d
L
Capacitor (inverter main circuit)C30~C37
For current detection
RSH01,RSH1
Linear expansion valve (for the control of
evaporating temperature)
Choke coil
(for high frequency noise reduction)
LEV4 For opening/closing the injection circuit
For opening/closing the defrost
circuit
SV10,11
Heat exchanger outlet pipe
temperature
TH9,11
12
L3
red
CNPS
1
3
2
1
TP1 TP2
TB3
2
3
TB7
M1 M2 M1 M2 S
1
512 34
1
2
t
°
1
2
132
3
4
6
3
6
1
5
31
2
2
CN82
blue
1
3
4
CN83
black
L1
L2
31
Fan motor
(Heat exchanger)
U
V
W
CNINV
7
1
4
34
CN4
black
1
13
231
t
3
SW001
1
4
°
CN2
1
12
1
3
31
432
2
3
1
1
CNSNR
TH4
t
4
°
1
1
1
CN211
green
23
123
321
U
5
Transformer Box
CNTR3
3
4
CNTR2
T02
(Transformer)
2
2
3
4
T03
(Transformer)
1
1
2
5
4
3
2
1
1
3
2
1
23
1
2
3
1
CN6
21
°
t
2
yellow
CNPOW
t
°
1
654
X10
ON
X08
Unit address
setting
CT12
CN5
red
D1
R4
-
Z5
1
+
3
1
6
CNTR1
12
L1 L2 L2
3
L3
45678
RSH01
white
Ground
12
34
3
white
red
black
black
white
red
F4
AC600V
6A F
F5
AC600V
6A F
green
CN62
CN990
green
CNTYP4
F4
AC250V
6.3A T
R5
CN201
Z25
1
TH5
2
SWU2
LED1
SW6
10
Control Board
CN40
63HS1
CN41
TH7
15
2
3
4
1
SW4
LED3
5
LEV5a
3
3
SET UP(SW6-10)
SC-V
CT22
SC-U
V
CN4
blue
red
M
OFF
t
black
CN506
red
CNTYP2
black
6
yellow
CN3K
*3
Compressor ON/OFF output
Error detection output
TB21
DC12V
CN51
SV5b
CN1A
U
CN2
blue
CN3N
1
3
+
3
4
TB1
CN1B
TB7 Power
selecting
connector
CNVDC
1
IPM
2
5
6
L3
DCL
black
72C
white
red
26
ON
OFF
M-NET power
supply circuit
12
M-NET Board
Power failure
detection circuit
Indoor/Outdoor
transmission
cable
INV Board
red
TB23
L2L1
+
ON
1's
digit
THHS
CN102
C31,C33,
C35,C37
1
4
1
W
10's
digit
OFF
LED2:Normal operation(Lit)
/ Error(Blink)
yellow
CNDC
red
red
MS
3
~
2
C100
*5
TH6
U
LED1:Power supply to
Indoor/Outdoor
transmission line
ZNR400
+
black
Central control
transmission
cable
*6
SC-L1
ONOFF
FT-N
R30,R32,
R34
Motor
(Compressor)
red
CN3S
1
CN04
red
CN43
1
SC-P2
P
CN61
green
CN202
red
C30,C32,
C34,C36
8
N
CN1
LED1: Normal operation(Lit)
/ Error(Blink)
*4
SC-W
SC-L3
2
P
63H1
4
1
SW5
10
5
CN3D
1
CPU power
supply circuit
black
CNAC2
1
*3
ONOFF
10
SWU1
white
CN212
red
SC-L2
6
2
CN80
F301
DC700V
4A T
CNTYP5
green
LED4:CPU in operation
LED1:Normal operation(Lit)
/ Error(Blink)
CN801
red
5
°
IPM
4
SC-P1
FT-P
black
red
DB1
CT3
C1
CNTYP
black
black
TB22
SWP1
RSH1
R6
C11
FAN Board
63LS
ZNR1
U
L
Noise
Filter
Z24
2
CN507
black
3
3
6
4
CN213
green
CN6
yellow
SV9
Function
setting
LED1
Display
setting/
Function
setting
72C
Noise filter
Noise filter
6
7
red
Surge
absorber
1
2
1
CN LVA
1
F01
AC250V
3.15A T
MS
3~
white black
1
CNIT
red
L1 L2 L3
R31,R33,
R35
3
4
1
R1,R5
X05
X06
3
5
1
6
CN505
13
X13
SV4d
X14
X12
1
6
3
CN508
blue
1
6
3
CNAC
CN81
green
12
5
1
3
4
SV4a
SV4b
4
4
CN2
C310,C311
SV1a
21S4a
5
Power Source
3~
60Hz
460V
1
2
3
4
6
M
CNLVE
LEV4
yellow
TH9
TH11
t
°
2
CNS2
CN509
yellow
X04
3
1
yellow
SV11
CN504
X03
3
1
green
CN503
SV10
green
CN72
yellow