150
-
'20 • KX-T-373
Information to identify the model(s) to which the information relates : FDC155KXZEN1-W
Outdoor side heat exchanger of heat pump :
air
Indoor side heat exchanger of heat pump :
air
Indication if the heater is equipped with a supplementary heater :
if applicable : electric motor
Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.
Item Symbol Value Unit Item Symbol Value Unit
Rated heating capacity
Seasonal space
heating energy η s,h
efficiency
Declared heating capacity for part load at indoor temperature 20
Declared coefficient of performance or gas utilization efficiency /
and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj
T
j
=-7
Pdh
9.1
kW T
j
=-7
COPd or
GUEh,bin / AEFh,bin
T
j
=+2
Pdh
5.6
kW T
j
=+2
COPd or
GUEh,bin / AEFh,bin
T
j
=+7
Pdh
3.6
kW T
j
=+7
COPd or
GUEh,bin / AEFh,bin
T
j
=+12 Pdh
3.6
kW T
j
=+12 COPd or
GUEh,bin / AEFh,bin
T
biv
=bivalent temperature Pdh
10.3
kW T
biv
=bivalent COPd or
temperature
GUEh,bin / AEFh,bin
T
OL
=operation limit Pdh
8.8
kW T
OL
=operation limit COPd or
GUEh,bin / AEFh,bin
For air-to-water heat pumps : Pdh
-
kW For air-to-water heat COPd or
T
j
=-15 pumps:T
j
=-15 GUEh,bin / AEFh,bin
(if T
OL
-20
) (if T
OL
-20
)
Bivalent temperature
T
biv
-10.0
For water-to-air heat
pumps:Operation limit
Degradation
T
ol
temperature
coefficient
C
dh
-
heat pumps**
Power consumpiton in modes other than 'active mode' Supplementary heater
back-up heating capacity
Off mode
P
OFF
0.006 kW
Thermostat-off mode
P
TO
0.031 kW
Type of energy input
Crankcase heater mode
P
CK
0.025 kW
Standby mode
Other items
For air-to-air heat pumps:
Capacity control
variable
air flow-rate,outdoor measured
Sound power level, For water-/brine-to-air heat pumps :
outdoor measured Rated brine or water fiow-rate,
outdoor side heat exchanger
Emissions of nitrogen mg/kWh
oxides(if applicable) fuel input
GCV
GWP of the
kg CO
2eq
refrigerant
(100years)
Mitsubishi heavy industries thermal systems,LTD
** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.
*** from 26 September 2018
Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance
of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.
NOx
***
-
675
Contact details
4920
m
3
/h
L
WA
73.0 dB
-
m
3
/h
elbu - kW
P
SB
0.006 kW
0.25
255.0 %
224.0 %
- %
-
663.0 %
896.0 %
%
296.0 %
417.0 %
180.1
No
Prated,h 15.5 kW
C
PSA012J092C