EasyManua.ls Logo

Mitsubishi KXZ Series - 12. OPTION PARTS; 12.1 Wireless kit

Mitsubishi KXZ Series
356 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-
293
-
'20 • KX-T-373
PJF000Z632
'20 PAC-T-352
-
18
-
(1) Specification
5. WIRELESS KIT
FDT series(RCN-T-5BW-E2, RCN-T-5BB-E2)
Receiver
Installation position of wireless kit
Refrigerant pipe Drain pipe
Notes
(1)Receiver can install the position as shown.
(2)Two LR03 AAA dry cell batteries for remote
control are enclosed.
(3)See spec sheet of "Wireless remote control"
about remote control.
Do not install the wireless kit at the following places
in order to avoid malfunction.
Installation of wireless kit
(1)Places exposed to direct sunlight
(2)Places near heat devices
(3)High humidity places
(4)Hot surface or cold surface
enough to generate condensation
(5)Places exposed to oil mist or steam directly
(6)Uneven surface
(7)Places affected by the direct airflow of the AC
unit
(8)Places where the receiver is influenced
by the fluorescent lamp(especially inverter type)
or sunlight
(9)Places where the receiver is affected by infrared
rays of any other communication devices
(10)Places where some object may obstruct the
communication with the remote control
Setting switch on PCB of receiver
SW3
SW4
SW2
SW1
Prevent interference
during plural setting
Receiver master/
slave setting
Buzzer
Auto restart
ON:Normal
OFF:Remote
ON:Master
OFF:Slave
ON:Valid
OFF:Invalid
ON:Valid
OFF:Invalid
Default setting: mark
Receiver
205
205
167
60
24
65
75
23 45
32.5
Remote control
Remote control holder
Wireless remote control's operable area
Standard reachable area of the signal
[condition] Illuminance at the receiver:300lux
(When no lighting is installed within 1m of the
receiver in an ordinary office.)
Correlation between illuminance at the receiver and
reachable area of the signal in a plain view.
The drawing in the right shows the correlation between the
reachable area of the signal and illuminance at the receiver
when the remote control is operated at 1m high under
the condition of ceiling height of 2.4m.
When the illuminance becomes double,
the area is narrowed down to two thirds.
3
Installation tips when several receivers are installed close
Minimum distance between the indoor units which can avoid
cross communication is 5m under the condition of 300lux of
illuminance at the receiver.
(When no lighting is installed within 1m
of the receiver in an ordinary office.)
Unit:mm
2
1
PJF000Z632
12.
OPTION PARTS
12.1 Wireless kit
(1) FDT series(RCN-T-5BW-E2, RCN-T-5BB-E2)
(a) Specification

Table of Contents