-
47
-
(3) Wall mounted type (FDK)
All models
CNTA
BL
12
Thi-A
CNI
BL
CNJ1
WH
6
5
4
3
2
1
CNN
YE
Thi-R3
Thi-R2
Thi-R1
t°
t°
t°
2
1
CNC
WH
CNH
BK
12
t°
DM
12
CNR
WH
M
2
1
RD
RD
RD
RD
YE
BK
BK
YE
FS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
+12+12
YG
BKBK
RDWH
LM4LM1 LM2 LM3
MM
1
M M
BK
2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5
BK BK BK BK BK BK BK BK BK RD RD RD RD RD RD RD RD RD RD
E1
CNL
BK
3
1
2
BK
BK
BK
Option
(volt-free contact)
HS
BK
BK
Remote operation input
BK BK BK BK BK BK BK BK BK BK RD RD RD RD RD RD RD RD RD RD
CNJ3
WH
PIS
3
1
2
t°
Remote control
Thc
M
CNA
RD
CNJ2
GY
AM4AM1 AM2 AM3
CNM1
WH
F2
CNB
BK
CNK1
WH
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
SM
WHYE
OR
BL
RD
XR1
XR5
CNT
BL
For heat recovery 3-pipe systems
(20S)
(SVH)
(SVG)
(SVE)
XB1
Prepare on site
XB2
XB3
XB4
XR2
XR3
XR4
1
2
3
4
5
6
CNT2
RD
1
2
3
4
5
X
Y
A
B
X
Y
TB2
WH
BK
BL
RD
L
N
Power source line
TB1
Connector for branching control
of heat recovery 3-pipe systems
CNU
BL
WH
RD
Earth
YG
1 2 3 4 5 6
+12
+12
(2.0A)
※1
MM
1
M M
2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5
WH WH WH WH WH WH WH WH WH WHBL
BL BL
BL BLBL BL BL BL
BL
F1
CNWO
WH
135
YG
RD
(3.15A)
WH
Power circuit
Indoor unit PCB
1
2
1
2
(Operation)
(Heating)
(Thermo ON)
(Inspection)
Remote operation input
(volt-free contact)
Signal line
between indoor units
Signal line
(Shielded cord)
Power source line
between indoor units
CNJ4
WH
WH WH WH WH WH WH WH WH WH WHBL BL BL BL BL
BL
BL
BL BL
BL
FMi
M
1 4 5 6 7
BLRD BR OR WH
CNM2
WH
BLRD BR OR WH
Operation check,drain pump motor test run
Temperature sensor
(Remote control)
Model capacity setting
SW6,SW7-2
Terminal block(Power source)( □ mark)
TB1
TB2
Stepping motor(For electronic expansion valve)
SM
SW1
SW2
Indoor unit address:tens place
Indoor unit address:ones place
SW3
SW4
Automatic adjustment / Fixed previous
SW5-1
SW5-2
SW7-1
Thi-A
Thi-R1,2,3
Thc
Outdoor unit address:tens place
Outdoor unit address:ones place
Indoor unit address:hundreds place
Terminal block(Signal line)( □ mark)
Temperature sensor
(Return air)
Temperature sensor
(Heat exchanger)
version of Superlink protocol
Drain pump motor
Fan motor
DM
FuseF1,2
ConnectorCNA-Z
FMi
DescriptionItem
Draft prevention function motorAM1-4
Louver motor
Float switch
LM1-4
FS
Indication lamp(Red-Inspection)
LED・2
Indication lamp(Green-Normal operation)
LED・3
JSL1
Spare Superlink connector change
PIS Motion sensor
Color marks
Meaning of marks
Mark Color
Blue
BK
BL
Brown
Orange
BR
OR
Red
RD
Black
Mark Color
Yellow
WH
YE
Gray
YellowGreen
GY
YG
White
Humidity sensor
HS
SW2SW1
SW4SW3
SW6SW7
CNK2
Superlink(spare)
JSL1
BK
LED・3LED・2
SW5
Prepare on site
Power source
1Phase
220-240V 50Hz
220V 60Hz
1. indicates wiring on site.
2.Use twin core shielded cord(0.75-1.25mm ) at signal line between
2
indoor unit and outdoor unit, and signal line between indoor units.
3.Use twin core cord(0.3mm ) at remote control line.
2
See spec sheet of remote control in case that the total length is more than 100m.
4.Do not put signal line and remote control line alongside power source line.
Notes
5.Draft prevention function(※1) is provided on the panel TC-PSAE-5AW-E, TC-PSAGE-5AW-E only.
431 5 6
4
56 23 1
WH
RD
CNTA
BL
12
CNJ1
WH
654321
CNN
YE
Th
i
-R3Th
i
-R2Th
i
-R1
t°
t°
t°
2
1
CNC
WH
HS
CNH
BK
FM
i
M
Power circuit
F1
CNWO
WH
1
3
5
M M M
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
B
K
R
D
W
H
Y
E
B
L
+12
+12
(Remote operation input
Indoor unit PCB
M
CNA
RD
SM
W
H
Y
E
O
R
B
L
R
D
1 2 3 4 5 6
B
K
CNK1
WH
1
2
BL
RD
B
A
TB2
21
Th
i
-A
t°
Remote control
Thc
t°
X
Y
X
Y
TB2
W
H
CNB
GN
1
2
SW5
SW7
SW2
SW6
SW1
SW4
SW3
CNK2
Superlink(spare)
JSL1
BK
TB1
YG
N
L
Connector for branching
control of heat recovery
3-pipe systems
CNU
R
D
W
H
(20S)
(SVH)
(SVG)
(SVE)
XB1
XB2
XB3
XB4
CNT2
RD
+12
Prepare on site
(Thermo ON)
(Operation)
(Inspection)
(Heating)
LM1 LM2 LM3
21 43 5
XR3
XR5
XR4
XR1
XR2
1 2 3 4 5 1 2 3 4 5 1 2 3 4
B
L
P
K
B
R
O
R
R
D
YE/GN
BL
Power souce
line
Earth
Power souce line
between indoor units
:volt-free contact)
(Remote operation input
:volt-free contact)
For heat recovery
3-pipe systems
Signal line
between indoor units
Signal line
(Shielded cord)
YG
B
K
B
K
B
K
B
K
B
K
B
K
B
K
B
K
B
K
B
K
B
L
P
K
B
R
O
R
R
D
B
L
P
K
B
R
O
R
R
D
CNI
BL
CNM1
WH
B
K
R
D
W
H
Y
E
B
L
CNF1
WH
431 5 6
※1
Indication lamp(Green-Normal operation)
LED・2
F1
Fuse
FMi
SW5 -1
Fan motor
Automatic adjustment/Fixed previous
SW3
Outdoor unit address:tens place
SW4
Outdoor unit address:ones place
Item Description
CNA-Z
Connector
HS
Humidity sensor
TB1
Terminal block(Power source)(□ mark)
Thc
Th
i
-A
Th
i
-R1,2,3
Temperature sensor(Return air)
Temperature sensor(Heat exchanger)
Temperature sensor(Remote control)
TB2
Terminal block(Signal line)(□ mark)
JSL1
Spare Superlink connector change
LED・3
Indication lamp(Red-Inspection)
version of Superlink protocol
SW7 -1
Operation check
SW6,SW7-2
Model capacity setting
LM1
Flap motor
SW5 -2
Indoor unit address:hundreds place
SW2
SW1
LM2
Louver motor(Left)
SM
Indoor unit address:ones place
Indoor unit address:tens place
Stepping motor(For electronic expansion valve)
LM3
Louver motor(Right)
BK Black
Blue
Color marks
BL
Mark Color
RedRD
WH White
YE Yellow
YG Yellow Green
BrownBR
OR Orange
PinkPK
Mark Color
PIS
Motion sensor
CNT
BL
CNL
BK
LED・2 LED・3
PIS
W
H
R
D
B
K
※2
Option
W
H
R
D
B
K
1 2 3
1 2 3
■mark
Closed-end connector
Notes
1. ----- indicates wiring on site.
2. Use twin core shielded cord(0.75 - 1.25mm
2
) at signal line between indoor unit
and outdoor unit, and signal line between indoor units.
3. Use twin core cord(0.3mm
2
) at remote control line.
See spec sheet of remote control in case that the total len
gth is more than 100m.
4. Do not put signal line and remote control line alongside pow
er source line.
5.
Fuse(F1)(※1)is 3.15A in case of FDK15~56 ,and 5A in case of FDK
71,90.
6.
Section 1(※2)shows electric circuit of motion sensor(option).
Meaning of marks
Power source
1 Phase
PHA001Z178