SERVICE DATA
2-9
Clearance of stop solenoid to plunger rack
ETR ETS
0.3 to 0.7
[0.0118 to
0.0276]
0.15 to 0.20
[0.0059 to
0.0079]
Resistance value of glow plug
12 V
0.2 Ω
24 V
4.5 Ω
Table 2-7 Maintenance service data table - Electrical system(3 / 3) Unit: mm [in.]
Inspection point Nominal Standard Limit Remark