What does memory error 2 mean on Mitsubishi Amplifier?
- JJames WilliamsSep 5, 2025
Memory error 2 (EEP-ROM) on your Mitsubishi Amplifier can occur due to: * EEP-ROM error at power on. * EEP-ROM error during operation.
What does memory error 2 mean on Mitsubishi Amplifier?
Memory error 2 (EEP-ROM) on your Mitsubishi Amplifier can occur due to: * EEP-ROM error at power on. * EEP-ROM error during operation.
Why does my Mitsubishi MR-J4-20A Amplifier show an overvoltage error?
An overvoltage error in your Mitsubishi Amplifier is due to a main circuit voltage error.
What does encoder normal communication error 2 mean on Mitsubishi MR-J4-20A Amplifier?
Encoder normal communication error 2 on your Mitsubishi Amplifier can be caused by: * Encoder data error 1. * Encoder data update error. * Encoder data waveform error. * Encoder non-signal error. * Encoder hardware error 1. * Encoder hardware error 2. * Encoder data error 2.
What causes a servo control error on my Mitsubishi MR-J4-20A?
A servo control error on your Mitsubishi Amplifier (specifically for linear servo motors and direct drive motors) can be caused by: * Servo control error by position deviation. * Servo control error by speed deviation. * Servo control error by torque/thrust deviation. * Fully closed loop control error by position deviation. * Fully closed loop control error by speed deviation. * Fully closed loop control error by position deviation during command stop.
What does a board error on my Mitsubishi MR-J4-20A mean?
A board error on your Mitsubishi Amplifier indicates: * Board error 1. * Board error 2. * Board error 3.
What causes a regenerative error in my Mitsubishi MR-J4-20A?
A regenerative error in your Mitsubishi Amplifier can stem from: * Regeneration heat error. * Regeneration signal error. * Regeneration feedback signal error.
What does parameter error mean on my Mitsubishi MR-J4-20A?
A parameter error on your Mitsubishi Amplifier indicates either a parameter setting range error or a parameter combination error.
What causes undervoltage on Mitsubishi MR-J4-20A Amplifier?
Undervoltage in your Mitsubishi Amplifier can be due to: * Voltage drop in the control circuit power. * Voltage drop in the main circuit power.
Why is my Mitsubishi MR-J4-20A Amplifier showing a servo motor overheat error?
A servo motor overheat error in your Mitsubishi Amplifier can be due to: * Abnormal temperature of servo motor 1. * Abnormal temperature of servo motor 2. * Thermistor disconnected error. * Abnormal temperature of servo motor 3. * Abnormal temperature of servo motor 4.
What causes a main circuit error in my Mitsubishi Amplifier?
A main circuit error in your Mitsubishi Amplifier can occur due to: * A ground fault detected by the hardware detection circuit. * A ground fault detected by the software detection function.
Series | MR-J4 |
---|---|
Type | AC Servo Amplifier |
Model | MR-J4-20A |
Voltage Class | 200 V |
Control Modes | Position, Speed, Torque |
Full-closed Control | Yes |
Advanced One-touch Tuning | Yes |
Real-time auto-tuning | Yes |
Vibration Tough Drive | Yes |
Safety Function | STO (Safe Torque Off) |
Communication Interface | SSCNET III/H |
Dynamic Brake | Built-in |
Rated Output Power | 0.2 kW |
Output Voltage | 200V |
Protective Functions | Overcurrent, Overvoltage |
Ambient Temperature | 0 to 55 °C |
Vibration Resistance | 5.9 m/s² |