1. TECHNICAL CHANGES ····································2
2. PART NAMES AND FUNCTIONS······················3
3. SPECIFICATION·················································5
4. NOISE CRITERIA CURVES·······························6
5. OUTLINES AND DIMENSIONS ·························7
6. WIRING DIAGRAM ············································8
7. REFRIGERANT SYSTEM DIAGRAM················9
8. SERVICE FUNCTIONS ····································10
9. TROUBLESHOOTING······································12
10. DISASSEMBLY INSTRUCTIONS·····················21
11. PARTS LIST······················································23
12. RoHS PARTS LIST···········································25
13. OPTIONAL PARTS···········································27
MSH-GA50VB -
MSH-GA60VB -
MSH-GA80VB -
E1
E1
E1
SPLIT-TYPE AIR CONDITIONERS
SERVICE MANUAL
Models
INDOOR UNIT
NOTE:
This service manual describes technical data of the indoor units.
RoHS compliant products have <G> mark on the spec name plate.
For servicing of RoHS compliant products, refer to the RoHS PARTS LIST (RoHS compliant).
Outdoor unit service manual
MUH-GA•VB Series (OB368)
No. OB367
REVISED EDITION-D
Revision D:
• Parts numbers of indoor fan motor and
motor band have been changed.
• Some descriptions have been modified.
Please void OB367 REVISED EDITION-C.
OB367D-1.qxp 12.1.13 7:49 AM Page 1
Downloaded from AC-Manual.com Manuals

Questions and Answers

  • L
    lorimuellerAug 9, 2025
    What to do if my Mitsubishi Air Conditioner indoor control system is not working?
    • M
      marynealAug 9, 2025
      If the indoor control system of your Mitsubishi Air Conditioner is not working, check the indoor electronic control P.C. board.
  • M
    Marcus BrownAug 14, 2025
    What to do if my Mitsubishi MSH-GA50VB flashes 4 times?
    • D
      David JonesAug 14, 2025
      If your Mitsubishi Air Conditioner flashes 4 times, it indicates a problem with the indoor unit control system. Replace the indoor electronic control P.C. board.
  • L
    Leslie SmithAug 19, 2025
    What does it mean if my Mitsubishi Air Conditioner flashes 2 times?
    • C
      Chad FischerAug 19, 2025
      A 2-time flash on your Mitsubishi Air Conditioner indicates a problem with the room temperature or indoor coil thermistor. Check the room temperature thermistor and the indoor coil thermistor.
  • T
    Tammy JenkinsAug 25, 2025
    What does it mean if my Mitsubishi Air Conditioner flashes 3 times?
    • R
      Rachel HortonAug 25, 2025
      A 3-time flash on your Mitsubishi Air Conditioner signals a problem with the indoor fan motor.
  • C
    Craig Cruz Jr.Aug 30, 2025
    What does it mean if my Mitsubishi Air Conditioner flashes 6 times?
    • B
      banksmatthewAug 30, 2025
      A 6-time flash on your Mitsubishi Air Conditioner indicates a problem with the thermistor in the outdoor unit.
  • J
    james64Sep 3, 2025
    What does it mean if my Mitsubishi MSH-GA50VB flashes on and off at 0.5-second intervals?
    • E
      Erika CarterSep 3, 2025
      A flash on and off at 0.5-second intervals on your Mitsubishi Air Conditioner indicates mis-wiring in the indoor or outdoor unit.

Mitsubishi MSH-GA50VB Specifications

General IconGeneral
Cooling Capacity5.0 kW
Power Supply220-240V, 50Hz
RefrigerantR410A
Outdoor Unit Dimensions (W x H x D)800 x 550 x 285 mm
Weight (Indoor Unit)10 kg
TypeSplit System