Page #322 background imageLoading...
Page #322 background image
6 - 22
6.5 Clock Function
6
FUNCTIONS
(6) Accuracy of Clock Data
The accuracy of the clock function differs with the ambient temperature, as shown
below:
(7) Comparison of Clock Data
To compare High Performance model QCPU's clock data with a sequence program,
use the DATERD instruction to read the clock data.
Since the clock data read instruction (DATERD) reads the year data in four digits, the
data can be compared by the comparison instruction without making any
modifications.
Table6.7 Accuracy of Basic model QCPU
Ambient Temperature ( )
Accuracy (Day difference, S)
0 - 3.2 to + 5.27(TYP.+ 1.98)
+ 25 - 2.57 to + 5.27(TYP.+ 2.22)
+ 55 - 11.68 to + 3.65(TYP.- 2.64)
Table6.8 Accuracy of High Performance model QCPU and Process CPU
Ambient Temperature ( )
Accuracy (Day difference, S)
0 - 3.18 to + 5.25(TYP.+ 2.12)
+ 25 - 3.93 to + 5.25(TYP.+ 1.9)
+ 55 - 14.69 to + 3.53(TYP.- 3.67)
Table6.9 Accuracy of Redundant CPU
Ambient Temperature ( )
Accuracy (Day difference, S)
0 - 3.2 to + 5.27(TYP.+ 2.07)
+ 25 2.77 to + 5.27(TYP.+ 2.22)
+ 55 - 12.14 to + 3.65(TYP.- 2.89)
Table6.10 Accuracy of Universal model QCPU
Ambient Temperature ( )
Accuracy (Day difference, S)
0 - 2.96 to + 3.74(TYP.+ 1.42)
+ 25 - 3.18 to + 3.74(TYP.+ 1.50)
+ 55 - 13.20 to + 2.12(TYP.- 3.54)

Table of Contents

Other manuals for Mitsubishi Q02HCPU

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Q02HCPU and is the answer not in the manual?

Mitsubishi Q02HCPU Specifications

General IconGeneral
BrandMitsubishi
ModelQ02HCPU
CategoryController
LanguageEnglish