EasyManua.ls Logo

Mitsubishi QD75M4 - Basic Parameters 2

Mitsubishi QD75M4
882 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 - 26
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
5.2.2 Basic parameters 2
Setting value, setting range
Setting value buffer memory
address
Item
Value set with peripheral device
Value set with sequence
program
Default
value
Axis 1 Axis 2 Axis 3 Axis 4
Pr.8
Speed limit value
The setting range differs depending on the "
Pr.1
Unit setting".
Here, the value within the [Table 1] range is set.
[Table 1] on right page
200000
10
11
160
161
310
311
460
461
Pr.9
Acceleration time 0
1 to 8388608 (ms) 1 to 8388608 (ms) 1000
12
13
162
163
312
313
462
463
Pr.10
Deceleration time 0
1 to 8388608 (ms) 1 to 8388608 (ms) 1000
14
15
164
165
314
315
464
465

Table of Contents

Related product manuals