5 - 52
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
Setting value, setting range
Setting value buffer memory
address
Item
Value set with peripheral device
Value set with sequence
program
Default
value
Axis 1 Axis 2 Axis 3 Axis 4
Pr.47
Creep speed
The setting value range differs depending on the
Pr.1
Unit
setting.
Here, the value within the [Table 1] range is set.
[Table 1] on right page
1
76
77
226
227
376
377
526
527
0 : Do not retry OPR with limit
switch
0
Pr.48
OPR retry
1 : Retry OPR with limit switch 1
0 78 228 378 528
Pr.47
Creep speed
Set the creep speed after near-point dog ON (the low speed just before stopping
after decelerating from the OPR speed).
The creep speed is set within the following range.
(
Pr.46
OPR speed ) (
Pr.47
Creep speed)
ON
V
OPR start
Near-point
dog signal OFF
Zero signal
OPR speed
Pr.46
Creep speed
Pr.47