5 - 77
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
Setting Value, setting range
Value set with peripheral device
Setting value buffer memory
address
Servo amplifier setting invalid ( : Invalid, : Valid)
MR-
H-BN
MR-
H-BN4
MR-
J2-B
MR-
J2S-B
MR-
J2-Jr
MR-
J2M-B
Value set with sequence program
Default
value
Axis 1 Axis 2 Axis 3 Axis 4
4
Serial communication
baud rate selection
Serial communication
response delay time selection
Encoder output pulse setting selection
OPR set condition selection
1: is used to set up the setting
value.
(Hexadecimal)
H
0000
H
30133 30233 30333 30433
0 to 50000 0 30134 30234 30334 30434
0 to 1000 980 30136 30236 30336 30436
0 to 65535 4000 30138 30238 30338 30438
2: Set the parameter value and switch power off once (The parameter is transferred to servo amplifier from QD75), then switch it on
again to make that parameter setting valid.
4: You cannot change parameter "Serial communication response delay time setting" and "Serial communication baud rate setting".
5
: Don't use to the parameter (normal). Don't change setting value "Default value" by any means.