9 - 58 
MELSEC-Q
 
9   MAJOR POSITIONING CONTROL 
 
 Positioning data setting example 
 
[Reference axis and interpolation axis are designated as axis 1 and axis 2, 
respectively.] 
The following table shows setting examples when "2-axis circular interpolation 
control with sub point designation (INC circular sub)" is set in positioning data No. 
1 of axis 1. (The required values are also set in positioning data No. 1 of axis 2.) 
 
Axis 
 
Setting item 
Axis 1 
(reference 
axis) setting 
example 
Axis 2 
(interpolation 
axis) setting 
example 
Setting details 
Da.1 Operation pattern  Termination  – 
Set "Termination" assuming the next positioning data will not 
be executed. 
Da.2 Control system 
INC circular 
sub 
– 
Set incremental system, 2-axis circular interpolation control 
with sub point designation. 
Da.3 
Acceleration time 
No. 
1 – 
Designate the value set in "
Pr.25
 Acceleration time 1" as 
the acceleration time at start. 
Da.4 
Deceleration time 
No. 
0 – 
Designate the value set in "
Pr.10
 Deceleration time 0" as 
the deceleration time at deceleration. 
Da.5 
Axis to be 
interpolated 
2 – 
Set the axis to be interpolated (partner axis). 
If the self-axis is set, an error will occur. 
Da.6 
Positioning address/ 
movement amount 
8000.0 
µ
m 6000.0 
µ
m 
Set the movement amount. (Assuming that the "
Pr.1
 Unit 
setting" is set to "mm".) 
Da.7 Arc address 
4000.0 
µ
m 3000.0 
µ
m 
Set the sub point address. (Assuming that the "
Pr.1
 Unit 
setting" is set to "mm".) 
Da.8 Command speed 
6000.00 
mm/min 
– 
Set the speed during movement. (Designate the composite 
speed in "
Pr.20
 Interpolation speed designation 
method".) 
Da.9 Dwell time  500ms  – 
Set the time the machine dwells after the positioning stop 
(pulse output stop) to the output of the positioning complete 
signal. 
Axis 1   Positioning data No. 1 
Da.10 
M code  10  – 
Set this when other sub operation commands are issued in 
combination with the No. 1 positioning data. 
 
   Refer to section "5.3 List of positioning data" for information on the setting details.  
 
POINT 
 
Set a value in "
Da.8
 Command speed" so that the speed of each axis does not 
exceed the "
Pr.8
 Speed limit value". (The speed limit does not function for the 
speed calculated by the QD75 during interpolation control.)