12 - 38 
MELSEC-Q
 
12   CONTROL SUB FUNCTIONS 
 
[1]   Control details 
The following drawing shows the operation during a speed change. 
 
V
V1
V2
V3
t
Speed changes to V2.
Operation during 
positioning by V1.
Speed changes to V3.
Md. 40 In speed change processing flag
 
Fig. 12.22 Speed change operation 
 
[2]   Precautions during control 
(1)  Control is carried out as follows at the speed change during continuous path 
control.  
a)  When no speed designation (current speed) is provided in the next 
positioning data: 
  The next positioning data is controlled at the "
Cd.14
 New speed 
value".  
b)  When a speed designation is provided in the next positioning data: 
  The next positioning data is controlled at its command speed 
(
Da.8
). 
 
Positioning control
 P1
Designated speed in P2
Cd. 14  New speed value 
Next control
P2
Speed change
command
Designated speed in P1
[a] When no speed designation
     (current speed) is provided.
[b] When a speed designation 
 is provided.
 
Fig. 12.23 Speed change during continuous path control 
 
(2)  When changing the speed during continuous path control, the speed change 
will be ignored if there is not enough distance remaining to carry out the 
change.