EasyManuals Logo

Mitsubishi SCM40ZS-S User Manual

Mitsubishi SCM40ZS-S
335 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #222 background imageLoading...
Page #222 background image
-
221
-
'16 • SCM-T-199
(ii) Outdoor unit
Remote control
Indoor control PCB
Outdoor
main PCB
Location of trouble Description of trouble Repair method
Reference
page
Error code Red LED Red LED
Green
LED
Red
LED (2)
Keeps
flashing
Stays OFF
Keeps
flashing
2-time
flash
Installation, operation status
• Higher outdoor heat exchanger temperature
Repair
260
Outdoor heat exchanger
temperature sensor
Defective outdoor heat exchanger temperature sensor
Replacement, repair
of temperature
sensor
Outdoor main PCB
*• Defective outdoor main PCB (Defective temperature sensor input circuit)?
Replacement of
PCB
Stays OFF
Keeps
flashing
5-time
flash
Installation, operation status
• Higher discharge temperature
Repair
261
Discharge pipe temperature
sensor
• Defective discharge pipe temperature sensor
Replacement, repair
of temperature
sensor
Outdoor main PCB
*• Defective outdoor main PCB (Defective temperature sensor input circuit)?
Replacement of
PCB
Stays OFF
Keeps
flashing
8-time
flash
Outdoor heat exchanger
temperature sensor
Defective outdoor heat exchanger temperature sensor, broken wire or poor
connector connection
Replacement, repair
of temperature
sensor
262
Outdoor main PCB
*• Defective outdoor main PCB (Defective temperature sensor input circuit)?
Replacement of
PCB
Stays OFF
Keeps
flashing
8-time
flash
Outdoor air temperature
sensor
Defective outdoor air temperature sensor, broken wire or poor connector
connection
Replacement, repair
of temperature
sensor
263
Outdoor main PCB
*• Defective outdoor main PCB (Defective temperature sensor input circuit)?
Replacement of
PCB
Stays OFF
Keeps
flashing
8-time
flash
Discharge pipe temperature
sensor
Defective discharge pipe temperature sensor, broken wire or poor connector
connection
Replacement, repair
of temperature
sensor
264
Outdoor main PCB
*• Defective outdoor main PCB (Defective temperature sensor input circuit)?
Replacement of
PCB
Stays OFF
Keeps
flashing
1-time
flash
Outdoor main PCB,
compressor
• Current cut (Anomalous compressor over-current)
Replacement of
PCB
265• 266
Installation, operation status
• Service valve closing operation
Repair
Stay OFF
Keeps
flashing
4-time
flash
Outdoor main PCB
Anomalous outdoor main PCB commuication
Replacement of
PCB
267
Outdoor sub PCB
Anomalous outdoor sub PCB commuication
Stays OFF
Keeps
flashing
2-time
flash
Outdoor sub PCB
• Defective active filter
Repair
PCB replacement
268
Stays OFF
Keeps
flashing
ON
Fan motor
• Defective fan motor
Replacement
269
Outdoor main PCB
• Defective outdoor main PCB
Stays OFF
Keeps
flashing
1-time
flash
Power transistor error
(outdoor main PCB)
• Power transistor error
Replacement of
PCB
270
Stays OFF
Keeps
flashing
8-time
flash
Outdoor suction pipe sensor
Defective suction pipe temperature sensor, broken wire or poor connector
connection
Replacement, repair
of temperature
sensor
271
Outdoor sub PCB
Defective outdoor sub PCB (Defective temperature sensor input circuit)?
Replacement of
PCB
Stays OFF
Keeps
flashing
2-time
flash
Operation status
• Shortage in refrigerant quantity
Repair
272
Installation status
• Service valve closing operation
Service valve
opening check
Stays OFF
Keeps
flashing
3-time
flash
• Overload operation
• Overcharge
• Compressor locking
• Current safe stop
Replacement
273
Stays OFF
Keeps
flashing
2-time
flash
Compressor, outdoor main
PCB
Anomalous compressor startup
Replacement
274
Stays OFF
Keeps
flashing
7-time
flash
Compressor
Anomalous compressor rotor lock
Replacement
275
Notes (1) * mark in the description of trouble means that, in ordinary diagnosis, it cannot identify the cause denitely, and, if the trouble is repaired by replacing the
part, it is judged consequently that the replaced part was defective.
(2) This LED is installed on model SCM50ZS-S.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi SCM40ZS-S and is the answer not in the manual?

Mitsubishi SCM40ZS-S Specifications

General IconGeneral
BrandMitsubishi
ModelSCM40ZS-S
CategoryAir Conditioner
LanguageEnglish

Related product manuals