25
-
'15 • SRK-T-172
3. ELECTRICAL WIRING
U
MFM
BK
Color symbol
BL
BR
LB
YE
RD
YG
WH
Red
YellowGreen
White
Black
Blue
Brown
Light blue
Yellow
Symbol
Meaning of Marks
Parts name Symbol Parts name
Capacitor forCF
I
FM
I
FM
ZNR
FM
I
Fuse
Fan motor
Flap motor
Varistor
Th2
T
Room temp. thermistor
Heat exchanger thermistor
Terminal block
F
Th1
Power source
220230240V 50Hz
YG
LB
BR
Printed circuit board
T
YG
BL
BR
WH
BK
TO
OUTDOOR
UNIT
Th1
Th2
Wireless
R-Amp
Display
CNE
CNG
YE
WH
RD
M
CNW
IC15
ZNR
1
5
3
CNU
CF
I
52C-4 52C-3
52C
F
250V 3.15A
CONTROL BOX
1
2
Back up Sw
CNM
N
t°
1
FM
I
t°
(1) Indoor units
Models SRK10CRV-S, S1
SRK13CRV-S, S1