– 15 –
Temporary run operation
• The unit ON/OFF button on the unit operates ON/OFF temporarily when the remote control is not used.
Operation program
• OPERATION MODE : AUTO
• FAN SPEED : AUTO
• AIR FLOW : AUTO
• Operation starts by pressing the unit ON/OFF button; it stops if
you press the button again.
SELF CLEAN operation
1
To active CLEAN operation, press the CLEAN switch with
the tip of a ballpoint pen.
Every time the CLEAN switch is pressed, the display is
switched in the order of:
No display
■ CLEAN operation should be run after AUTO, COOL and DRY operation to remove the moisture from inside the indoor unit and control the
growth of mold and bacteria.
(CLEAN on) (CLEAN off)
• Two hours later, the air conditioner stops running automatically. To stop the
air conditioner immediately, press the ON/OFF button.
• CLEAN operation is not operated after FAN, OFF-TIMER and SLEEP op-
erations have finished.
• The indoor unit fan runs for about two hours in CLEAN operation.
• The RUN light illuminates during CLEAN operation.
• Pressing the SLEEP button during CLEAN operation cancels the CLEAN
operation and then the unit is set to SLEEP operation.
• This is not a function for removing mold, germs or grime that have already
adhered to the unit.
Auto restart function
■ What is auto restart function?
• Auto restart function records the operational status of the air-conditioner immediately prior to be switched off by a power cut, and then automati-
cally resumes operations after the power has been restored.
• The following settings will be cancelled:
1 Timer settings
2 HIGH POWER operations
• Auto restart function is set at on when the air-conditioner is shipped from the factory. Consult with your dealer if this function needs to be
switched off.
• When power failure occurs, the timer setting is cancelled. Once power is resumed, set the timer again.
NOTE
NOTE
3 sec.
1 sec.
ON
OFF
Unit ON/OFF button
• Do not hold the Unit ON/OFF button down for more than 5 seconds.
(Holding it down longer than 5 seconds sets the automatic cooling used during servicing or when relocating the air-conditioner.)