10
-
'13 • SRK-T-140
G
J
WIRELESS
R-AMP
DISPLAY
SN
CNGCNE
250V 3.15A
CNU
CNM
BACK UP SW
5
U
M
M
CNF
F M
S M
F
Va
DS
L
Blue
BlackBK
Red
BL
RD
WhiteWH
YellowGreenYG
ColorMark
Heat exch. sensor
Fan motor
Room temp. sensor
Flap motor
Diode stackDS
FuseF
ConnectorCNE
FM
Terminal blockTB
Description
Item
VaristorVa
SM
ThI
Th2
YellowY
Humidity sensor
HD
CNF
CNG
CNM
CNU
BK
YG
RD
Y
WH
YG
RD
BK
BOX,
CONTROL
3
2N
WH
6
TO OUTDOOR UNIT
1
1 3 4 5
RD
BK
BL
HEAT
EXCHANGER
WH
6 2 2 2
Th
I
Th
2
TB
t
t
HD
HEAT
EXCHANGER
PWB ASSY
RWA000Z250
3. ELECTRICAL WIRING
(1) Indoor units
Models SRK25ZMP-S, 35ZMP-S, 45ZMP-S