TCHT011
OUTLINES AND DIMENSIONS
6
Front side
46-1/16(1170)
9-1/2(241)
33-21/32(855)2-29/32(74)
14-3/8(365)
Emergency operation switch
(cooling/heating)
Terminal block for Outdoor unit
Terminal block for
MA-remote controller
Front side(Grille open)
Terminal block for power supply (option)
Filter hook
6-1/16(154)
4-27/32(123)
18-31/32(482)Liquid pipe
17-15/32(444)Gas pipe
Drain hose
5-9/32(134)
Min.9/32(7)
Center measurement hole
[3/32([2.5)
Knockout hole for
rear piping
2-15/16×18-29/32(75×480)
75-
[
3/16(
[
5.1)
Tapping
screw hole
Mount board
Wall hole for
right rear piping
Indoor unit outline
4-
[
11/32(
[
9) Bolt hole
Wall hole for
left rear piping
1/8(3)
R1-15/32(R37.5)
2-1/8(54)
0
5/8(15.5)
0
17-9/32(439)
0
17-9/32(439)
15-1/8(384)
13/32(10)
20-3/8(517.4)
17-7/8(454)
16-3/32(408.5)
15-1/8(384)
14-11/32(364)
12-3/8(314)
4-11/32(110)
2-3/8(60)
13/32(10)
18-5/16(465.5)
17-7/8(454)
16-3/32(408.5)
15-1/8(384.5)
14-11/32(364)
12-3/8(314)
4-11/32(110)
2-3/8(60)
1-1/4(32)
12-5/32(308.5)
31/32(25)
11-1/2(292)
11(279.5)
9-17/32(242)
7-9/16(192)
5-19/32(142)
4-29/32(125)
4-19/32(117)
3-15/16(100)
2-15/16(75)
1-31/32(50)
15-1/8(384)
0
13-3/4(349.2)
16-15/16(430.5)
1/2(12.5)
11-1/2(292)
10-13/32(264)
9-1/32(229.5)
8-17/32(217)
6-9/16(167)
5-3/32(129.5)
4-1/8(104.5)
3-7/16(87.5)
2-15/32(62.5)
1-15/32(37.5)
1/2(12.5)
2-1/8(54)
31/32(25)
0
12-1/4(311)
8-17/32(216.5)
13-11/32(339)
20-7/8(530.5)
7-7/16(189)
13-11/32(339)
17-11/16(449.2)
23-1/32(585)
23-1/32(585)
A
5/16(7.8)
3-1/32(77)
2-5/8(67)
2-9/16(65)
B
Knockout hole for piping
13/32(10.7)
2-9/16(65)
3-1/32(77)
3-7/16(87)
C
5/16(7.8)
2-9/16(65)
3-1/32(77)
2-5/8(67)
Louver(manual)
Vane(auto)
Knockout hole
for lower piping
Under side
BB
Receiver
DEFROST/STAND BY lamp
Operation lamp
2-19/32(66)
23/32(18)
1-1/4(32)
2-3/32(53)
1-3/16(30)
1-3/8(35)
Mount board
C
Knockout hole
for right piping
Right side
11-5/8(295)
3/16(5)
Left side
A
Knockout hole
for left piping
Top side
2-9/16(65.2)
5-17/32(140.3)
7/16(11)
17(431.7)16-11/16(423.7)
Air outlet
Air inlet
Min.1-7/8(48)
Min.9-27/32(250)
Required space(Indoor unit)
Min.3-31/32(100.5)
Min.8-21/32(220)
Min.2-1/16(52.3)
3
2
1
Refrigerant pipe: 3/8 O.D([9.52)
Refrigerant pipe: 5/8 O.D([15.88)
5/8([16) O.D
3 Drain hose
Piping connection
1 Liquid pipe
2 Gas pipe
Through hole
[2-15/16
([75)
[2-15/16~[3-5/32
([75~[80)
Sleeve
(purchased locally)
Flared connection: 5/8F
Flared connection: 3/8F
Effective length: 23-1/32 (585)
TPKA0A0241KA80A TPKA0A0301KA80A TPKA0A0361KA80A
Unit: inch (mm)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi TPKA0A0361KA80A and is the answer not in the manual?

Mitsubishi TPKA0A0361KA80A Specifications

General IconGeneral
BrandMitsubishi
ModelTPKA0A0361KA80A
CategoryAir Conditioner
LanguageEnglish

Related product manuals