12
Step 10 – Mount the Filter Cap Terminal Strips
Drawing 6 shows where to mount the 5 terminal strips which will be used for mounting the filter capacitors.
Use #6 hardware.
(5) (5) (5)
(5)
Step 11 – Mount the Danger Label
Drawing 6 shows where to mount the danger label. This sticker is mainly used to scare people away from the
amp if you have the steel cage removed. (When playing the amp, keep the steel cage fastened for safety).
DANGER
HIGH VOLTAGE
MAY BE PRESENT
ON FILTER CAPACITORS
DO NOT TOUCH!
SECTION 2 – Mounting of Front Components
Please refer to Drawing 7.
Step 1 – Mount Faceplate Label
Drawing 7 shows the faceplate label. Make sure and line up each hole in the sticker with each hole in the
chassis front and carefully stick it to the chassis.
Step 2 – Mount the Lamp Holder
Drawing 7 shows where to mount the lamp holder. Be sure to mount it so that its solder lugs point towards
the bottom opening of the chassis box. (Once the lamp holder is mounted you may screw in the bulb and then
the jewel).
Step 3 – Mount the Power Switch and Standby Switch
Drawing 7 shows where to mount the power switch and standby switch. Be sure to mount the standby switch
with its solder lugs directed toward the chassis top.
Standby Switch
Power Switch
Remove all 6 screws from the
terminals. You will not need
them for this project.
Take your time and line this up properly because the sticker
cannot be removed again without damaging it.