7 Specifications
RMS output power: . . . . . . . . . . . . . . 120 W
Peak output power: . . . . . . . . . . . . . . 160 W
Frequency range: . . . . . . . . . . . . . . . 100 – 15 000 Hz (±3 dB)
S/N ratio: . . . . . . . . . . . . . . . . . . . . . 92 dB
THD: . . . . . . . . . . . . . . . . . . . . . . . . . < 2 % at rated power (1 kHz)
Inputs CH 1 – CH 6
XLR/6.3 mm jack, CH 1 with additional screw terminals
(Input sensitivity, impedance, type of connection)
Switch position “MIC”: . . . . . . . . . 1.5 mV, 5 k
Ω
, balanced
Switch position “LINE”: . . . . . . . . . 270 mV, 10 k
Ω
, balanced
RCA jacks
Switch position “MIC”: . . . . . . . . . 26 mV, 5 k
Ω
, unbalanced
Switch position “LINE”: . . . . . . . . . 300 mV, 10 k
Ω
, unbalanced
Input RETURN: . . . . . . . . . . . . . . . . . 1 V, 10 k
Ω
, unbalanced
Output SEND: . . . . . . . . . . . . . . . . . . 1 V, 600
Ω
, unbalanced
Output SLAVE OUT: . . . . . . . . . . . . 1 V, 600
Ω
, unbalanced
Tone controls
BASS: . . . . . . . . . . . . . . . . . . . . . ±10 dB at 100 Hz
TREBLE: . . . . . . . . . . . . . . . . . . . ±10 dB at 10 kHz
Talkover attenuation (VOX): . . . . . . . . 40 dB
Power supply
Mains operation: . . . . . . . . . . . . . 230 V~/50 Hz
Power consumption: . . . . . . . . 320 VA max.
Emergency
power supply: . . . . . . . . . . . . . . . . 24 V
Power consumption: . . . . . . . . 7 A max.
Ambient temperature: . . . . . . . . . . . . 0 – 40 °C
Dimensions (W × H × D): . . . . . . . . . 430 × 88 × 340 mm, 2 RS
Weight: . . . . . . . . . . . . . . . . . . . . . . . 12 kg
Pin configuration of the input jacks CH 1 – CH 6 (9)
XLR
6.3 mm jack
Pin configuration of the jacks SEND (18) and RETURN (19)
6.3 mm jack
Pin configuration of the speaker jacks (17)
6.3 mm jack
Subject to technical modification.
T = signal
S = ground
T = signal + (+48 V phantom power)
R = signal
-
(+48 V phantom power)
S = ground
1 = ground
2 = signal + (+48 V phantom power)
3 = signal
-
(+48 V phantom power)
9
G
B
All rights reserved by MONACOR
®
INTERNATIONAL GmbH & Co. KG. No part of this instruction
manual may be reproduced in any form or by any means for any commercial use.