EasyManua.ls Logo

Monacor security DA-8000 - Test Mode; Performing System Walktesting

Monacor security DA-8000
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GB
18
12) With the button Yes it is possible to go to recent
events.
13) To terminate this function, press the button 0 three
times so that a signal will sound after exiting
the menu and the display shows date, time, and
<<< UNSET >>> again.
Meaning of the different indications
The user 1 activated the alarm control system on June
27 at 19h50 (7.50 p.m.).
The user 1 deactivated the alarm control system on
June 28 at 6.50 a.m.
The technician activated the alarm control system on
June 28 at 11.32 a.m.
An alarm was recorded on June 28 at 11.50 a.m. To
display the zone concerned, press the button No:
An alarm occurred in zone 3.
The mains supply was interrupted on June 17 at 22h09
(10.09 p.m.).
The power supplies by the 230 V mains and the
rechargeable battery were interrupted at the same
time. After the power supply is present again, the date
is reset to January 1 and the time to 0.00. In this case
date and time have to be readjusted (chapter 2.2).
One of the contacts in the common sensor anti-tamper
loop was opened on June 5 at 9.18 a.m.
Further possible anti-tamper messages:
Case Tamp tampering action at the alarm control
system
KP Tamper tampering action at a keypad controller
Bell Tamp tampering action at the alarm unit, siren,
or strobelight
5Test Mode
In the test mode all alarm sensors can successively be
triggered without response of the siren and the strobe-
light.
1) The alarm control system must be deactivated.
Enter a master access code (chapter 2.1). The
display shows e. g.:
2) Press the button No within 15 seconds, otherwise
the programming mode will be exited. The display
shows:
3) Press the button Yes. The display must now show:
4) Trigger all sensors successively. The buzzers of
the keypad controllers and the speaker connected
to the alarm control system will sound for the time
of the alarm recording. The display shows the cor-
responding zone in the meantime.
5) To test the siren and the strobelight, press the
numerical key 9. To switch off the siren and the
strobelight, press the button 9 again.
6) To switch off the test mode and exit the programm-
ing mode, press the button 0 three times so that
date, time, and <<< UNSET >>> are displayed
again.
Subject to technical modification.
Walktesting.....
Ok!
Do You Want to..
Test ?
Do You Want to..
Set User 1 ?
05 Jun 09:18
Tamper
01 Jan 00:04
W/dog
17 Jun 22:09
Mains Flt
28 Jun 11:50
Zone3
28 Jun 11:50
Alarm
28 Jun 11:32
On Engineer
28 Jun 06:50
Off User 1
27 Jun 19:50
On User 1