EasyManua.ls Logo

Monark Ergomedic 828 E - Freewheel Sprocket Replacement and Lubrication

Monark Ergomedic 828 E
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Monark Ergomedic 828 E
13
Service
Freewheel sprocket
When replacing the freewheel sprocket remove
left and right frame cover. Dismantle the chain as
described in part ”Chain 1/2” x 1/8” ”.
Loosen the axle nuts and lift off the flywheel.
Remove the axle nut, washer, chain adjuster and
spacer on the freewheel side. Place the special
remover (part No. 9100-14) in the adapter and
place the spacer and axle nut outside. See fig:
Special remover.
NOTE: Do not tighten the axle nut completely. It
must be possible to loosen the adapter-sprocket
half a turn.
The sprocket should be lubricated with a few
drops of oil once a year. Tolt the cycle somewhat
to make it easier for the oil to reach the ball bea-
ring. See fig: Lubrication.
Fig: Lubrication
Fig: Hub assembly
Fig: Special remover
(part no: 9100-14)