Eco Convection Ovens | 4/5/7/10-Tray | Steam Installation and Operation Manual
10
MONO FG1BX-UK-MAN-0100 | Rev. A23 (March 2023)
Electrical specifications
Power supply
WARNING An electrical socket must be protected by a 30mA Type A Residual Current Device
(RCD) before installation and commissioning of the oven.
Always fit a wall-mounted isolator switch to isolate the oven from the electrical supply
completely. The isolator must be visible, labelled clearly, and easily accessible by an
operator.
Always check electrical requirements on the nameplate before connecting the power.
Table 2: Oven supply specifications
4/5-Tray 240 Vac (50 Hz), 1 phase 7.5 kW, 40 Amps
380 Vac (50 Hz), 3 phase + neutral + earth (Contact the factory)
415 Vac (50 Hz), 3 phase + neutral + earth 7.5 kW, 11 Amps per phase
7-Tray 240 Vac (50 Hz), 1 phase 10 kW, 45 Amps
380 Vac (50 Hz), 3 phase + neutral + earth (Contact the factory)
415 Vac (50 Hz), 3 phase + neutral + earth 10 kW, 14 Amps per phase
10-Tray 380 Vac (50 Hz), 3 phase + neutral + earth (Contact the factory)
415 Vac (50 Hz), 3 phase + neutral + earth 17 kW, 32 Amps
Power cable
2.5 metres of cable factory-fitted with a LEGRAND (or equivalent) plug
Display
7-inch HD TFT resistive touchscreen, portrait format
Environmental specifications
Table 3: Environmental specifications
Noise level Less than 85 dB
Water supply Required
Drainage Not required