NOTICE CONSOLE CS 3000-16 CS 3000-32
SEED MONITOR CS 3000-16 CS 3000-32 MANUAL
COMPAGNIE RIBOULEAU
CS
3000-16
CS
3000-32-2013
-
Réf.
10640089

Table of Contents

Questions and Answers

  • B
    Brandon CochranAug 12, 2025
    How to fix row allocation configuration alarm on Monosem Farm Equipment?
    • M
      Mike WhiteAug 12, 2025
      If your Monosem Farm Equipment shows a row allocation configuration alarm, it means the console detects a number of sensors that doesn't match its programming. Check that all sensors are detected when you switch on the console and replace any faulty ones. If the sensor number is correct, reprogram the console. If the issue persists, contact our after-sales service team.
  • P
    Patrick SantosAug 27, 2025
    What to do if Monosem Farm Equipment shows faulty row alarm + high and low population alarm?
    • K
      kennethjohnsonAug 27, 2025
      If your Monosem Farm Equipment is showing a faulty row alarm along with high and low population alarms, first check the sower element. Then, clean the sensor with a brush to remove any fouling. If the problem persists, try swapping the connection of the suspect sensor with that of a neighboring sensor to see if the problem moves with the sensor, indicating a faulty sensor or wire harness.
  • E
    Emily CortezSep 4, 2025
    What causes forward speed absence alarm on Monosem CS 3000-16 Farm Equipment?
    • E
      Emily PhelpsSep 4, 2025
      If your Monosem Farm Equipment displays a forward speed absence alarm, check the speed sensor and its wiring. If the problem persists, contact our after-sales service team.
  • R
    rleSep 10, 2025
    What to do if the console won't switch on in Monosem Farm Equipment?
    • C
      Courtney JonesSep 12, 2025
      If the console of your Monosem Farm Equipment won't switch on, start by checking the fuse. If it's burnt, replace it with a 7.5 Amp fuse. If it burns again, inspect the wire harness for cuts or damage. Also, ensure the battery voltage is at least 10 volts; if not, recharge or replace the battery. Clean and retighten the battery connections, and repair or replace any faulty battery cables. Lastly, ensure the wires are correctly connected to the battery, paying attention to the battery's polarity. If the issue persists, contact our after-sales service team.