EasyManua.ls Logo

Montigo R320STN - User Manual

Montigo R320STN
38 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
XG0231 - 061120
Installation & Maintenance Manual
• Theinstallationofthisreplacemustbedonebya
qualiedandcertiedgasapplianceinstaller.
• Checklocalcodesandreadallinstructionspriorto
installation.
®
C
US
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury,
death, or property damage.
—Donotstoreorusegasolineorotherammablevaporsand
liquidsinthevicinityofthisoranyotherappliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phoneinyourbuilding.
• Leavethebuildingimmediately.
• Immediatelycallyourgassupplierfromaneighbour's
phone. Follow the gas supplier’s instructions.
• Ifyoucannotreachyourgassupplier,callthere
department.
—Installationandservicemustbeperformedbyaqualied
installer,serviceagencyorthegastter.
Exemplar See-Through
INDOOR DIRECT VENT GAS FIREPLACE
R320STN 45,000 BTU/hr NG
R320STL 42,000 BTU/hr Propane
R420STN 55,000 BTU/hr NG
R420STL 55,000 BTU/hr Propane
Read and understand this manual. Improper installation, adjustment,
alteration, service or maintenance can cause serious injury, property
damage or even death. For assistance or additional information
consult a qualied installer, service agency or the gas supplier.
A barrier designed to reduce the risk of burns from the
hot viewing glass is provided with this appliance and
must be installed for the protection of children and
other at-risk individuals.
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
Installation and service must be performed by a qualied installer,
service agency or the gas tter.
Installer: Leave this manual with the appliance.
Consumer: Retain this manual for suture reference.
NOTICE
CAUTION
DANGER
DANGER
Some materials used in the manufacturing process of this product can
expose you to Benzene which is known in the State of California to
cause cancer and birth defects or other reproductive harm. For more
information go to www.P65warnings.ca.gov
WARNING
R520STN 80,000 BTU/hr NG
R520STL 80,000 BTU/hr Propane
R620STN 100,000 BTU/hr NG
R620STL 100,000 BTU/hr Propane

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Montigo R320STN and is the answer not in the manual?

Overview

The provided document is an Installation & Maintenance Manual for the Montigo Exemplar See-Through Indoor Direct Vent Gas Fireplace.

Function Description:

The Montigo Exemplar See-Through is a direct vent gas fireplace designed for indoor use. It functions as a vented decorative gas appliance, meaning it is not intended as a primary heat source and is not for use with solid fuel. The "see-through" design allows for viewing the flames from two sides, making it suitable for installation in walls or as a room divider. The fireplace operates on either natural gas (NG) or liquid propane (LP) and utilizes a power vent system for exhaust. It features an automatic pilot ignition system (HSI Electronic Ignition/SIT Electronic Ignition (IPI)) and advanced safety controls to ensure safe operation. A barrier is provided to reduce the risk of burns from the hot viewing glass, which must be installed for the protection of children and other at-risk individuals.

Important Technical Specifications:

The manual covers several models within the Exemplar See-Through series, including R320ST, R420ST, R520ST, and R620ST, with variations for Natural Gas (STN) and Propane (STL).

  • Heat Output (BTU/hr):
    • R320STN: 45,000 (NG)
    • R320STL: 42,000 (Propane)
    • R420STN: 55,000 (NG)
    • R420STL: 55,000 (Propane)
    • R520STN: 80,000 (NG)
    • R520STL: 80,000 (Propane)
    • R620STN: 100,000 (NG)
    • R620STL: 100,000 (Propane)
  • Fuel Type: Natural Gas or Liquid Propane.
  • Gas Pressure Requirements (during operation):
    • Natural Gas:
      • Minimum inlet pressure: 5.5 in. w.c.
      • Manifold pressure: 3.5 in. w.c.
    • Propane:
      • Minimum inlet pressure: 11 in. w.c.
      • Manifold pressure: 10 in. w.c.
  • Electrical Rating: 115V/1Ph (or 208V/1Ph for >1.0HP PV)/60Hz/15A Dedicated (for R620-ST-I, R820 models). Power Vent 120V / 1Ph/60Hz/Less than 12A (for R320-ST-I, R720 models).
  • Altitude Rating: N & H (0-4500 ft. / 0-1371 m).
  • Vent Pipe Diameter: 5"/8" for R320 and R420 units, 5"/10" for R520 and R620 units.
  • Maximum Vent Run: 80' (R320ST, R420ST) and 100' (R520ST, R620ST) for multi-elbow installations. 80' (R320ST, R420ST) and 120' (R520ST, R620ST) for straight vertical, top vent, roof-mounted power vent. 100' for wall-mounted vent systems.
  • Maximum Elbows: 6 (90° elbows), 12 (45° elbows).
  • Clearances to Combustibles:
    • Sides/Côtés: 3"
    • Back/Derrière: 2" (R620), N/A (R320)
    • Top-Top Vent/Du Haut-Event Du Haut: 26"
    • Top-Rear Vent/Du Haut-Event Arrière: N/A
    • Floor/Plancher: 0"
    • Mantel/Manteau: 6"
    • Recess Depth/Profondeur D'Encadrement: 24.250 (R620), 24" (R320)
    • Flue: 1"
  • Control Box Dimensions: 9 5/8" (244mm) height, 11 7/8" (303mm) width, 7 3/8" (186mm) depth.
  • Framing Dimensions (Platform Height): Max 24" for 8' ceiling, Max 48" for 10' ceiling.

Usage Features:

  • See-Through Design: Allows for viewing the flame from two sides, enhancing aesthetic appeal in various architectural settings.
  • Automatic Pilot Ignition: Equipped with an advanced ignition system that automatically lights the pilot burner, eliminating the need for manual lighting.
  • Wall Switch Operation: The unit can be connected to a dry contact wall switch for easy on/off control.
  • Power Vent System: Ensures efficient exhaust of combustion by-products, allowing for flexible termination locations (roof or exterior wall).
  • Media Options: Supplied with firestones, with optional fireglass or cultured river rocks available for purchase, allowing for customization of the flame bed appearance.
  • Safety Barrier: Includes a barrier to reduce the risk of burns from hot viewing glass, crucial for homes with children or at-risk individuals.
  • Control Panel: Features LED indicators for power, combustion air switch, flue gas switch, and a power vent speed control for fine-tuning operation.
  • Conversion Capability: Units are shipped for Top Vent installations but can be converted to Rear Vent installations following specific instructions.

Maintenance Features:

  • Annual Inspection: The fireplace and its installation should be inspected yearly by a qualified service person. This includes checking the vent system, termination, explosion relief flappers, door gaskets, burner, primary air openings, gas valve, gas components, pilot flame, and all optional equipment.
  • Glass Cleaning: The glass window must be cleaned periodically to remove film (a normal by-product of combustion). Non-abrasive, non-ammonia based glass cleaners (such as Kel-Kem or White Off) are recommended. Abrasive cleaners should not be used as they can permanently etch the surface.
  • Firebox Cleaning: The control compartment, burner, and firebox should be kept free from dust and lint using a vacuum cleaner or whisk broom.
  • Gas Line Leak Check: After gas line connection, all connections, valves, and valve train must be checked under normal operating pressure with a liquid solution or leak detection device to identify and seal any leaks.
  • Flue Gas Switch Calibration Check: A procedure is outlined to check the calibration of the flue gas switch, ensuring proper safety operation.
  • Component Replacement: A list of replacement parts for Honeywell HSI and Control Board components is provided, including part numbers for NG/Propane Gas Valves, Pilot Assemblies, Power Vent Control Box, Fuse, Transformer, Pre/Post Purge Timers, and Rheostat.
  • Service Access: The fireplace control box should be installed in an accessible location for easy maintenance, adjustments, and service.
  • Warning for Water Exposure: If any part of the appliance has been under water, it must not be used. A qualified service technician must inspect the appliance and replace any affected control system or gas control parts.

Montigo R320STN Specifications