REGULAR INSPECTION B-25
14.1.2 Type 2 (Electrical Cabinet Side)
Change the battery with the power supply shut off.
Be sure to change the battery in less than 30 minutes.
The data stored in the memory will be lost if the power supply is shut off for 30 minutes
or more.
To avoid the danger of lost data, you are recommended to save the memory data to an
external I/O device.
Mori Seiki does not have any responsibility for the loss of memory data.
<Battery position>
The batteries are installed in the electrical cabinet door.
<Changing interval>
Every 5 years
When the battery alarm message is displayed on the screen.
<Procedure>
1) Press the NC power switch (off).
2) Turn off the power.
3) Remove the screws of the battery unit.
4) Pull out the battery unit.