MoTeC Appendices 59
CAN Bus Wiring Requirements
The CAN bus should consist of a twisted pair trunk with 100R (0.25 watt)
terminating resistors at each end.
o If the CAN bus is less than 2 meter (7 ft) long, a single termination
resistor may be used.
The preferred cable for the trunk is 100R data cable.
The maximum length of the bus is 16 meter (50 ft)
CAN devices (such as MoTeC Dash Loggers, ECUs etc) may be
connected to the trunk with up to 500 mm (20 in) of twisted wire.
CAN-LO
CAN-HI
100R
100
R
CAN-LO
CAN-HI
CAN
Device
500 mm
max
<< CAN Bus >>
500 mm max
100R Terminating
Resistors at each
end of the CAN Bus
CAN-LO
CAN-HI
CAN
Device
CAN-LO
CAN-HI
CAN
Device
These wires must be twisted
Minimum one twist per 50 mm (2 in)