24 AP-0622 Access Point
4.3 AP-0622 External Antenna Model Electrical Characteristics
An AP-0622 External Antenna model Access Point has the following electrical characteristics:
4.4 AP-0622 External Antenna Model Physical Characteristics
An AP-0622 External Antenna model Access Point has the following physical characteristics:
Operating Current &
Voltage
12VDC, 1A (accessory power connector)
48V,0.25A (PoE connector)
Dimensions 7.88 inches x 5.00 inches x 1.00 inches
20.01 cm x 12.70 cm x 2.54 cm
Housing Metal
Weight 1.45 lbs / 0.65 kg
Operating
Temperature
32°F to 104°F/0°C to 40°C
Storage Temperature -40°F to 185°F/-40°C to 85°C
Operating Humidity 5 to 95% Relative Humidity non-condensing
Storage Humidity 85% Relative Humidity non-condensing
Operating Altitude
(max)
8,000 ft @ 28C
Storage Altitude
(max)
30,000 ft @ 12C
Electrostatic
Discharge
+/-15kV Air and +/-8kV Contact @ 50% Relative Humidity