30 AP-7522 Access Point
4 AP-7522 Access Point Specifications
4.1 Electrical Characteristics
An AP-7522 Access Point has the following electrical characteristics:
4.2 Physical Characteristics
An AP-7522 Access Point has the following physical characteristics:
Operating Current &
Voltage
12VDC, 1A (AUX input voltage)
12VDC PWRS-14000-54R power supply
48VDC, 0.375A (POE)
802.3at AP-PSBIAS-2P3-ATR Power Injector
Dimensions 7.1 in. L x 6.5 in. W x 1.6 in. H
180 mm L x 165 mm W x 41 mm H
Housing Plenum-rated housing (UL2043)
Weight 1.8 lbs/0.82 kg
Operating
Temperature
External antennas: -4° F to 104° F/-20° C to 40° C
Internal antennas: 32° F to 104° F/0° C to 40° C
Storage Temperature -40° F to 158° F/-40° C to 70° C
Operating Humidity 85% RH non-condensing
Operating Altitude
(maximum)
8,000 ft @ 28C
Storage Altitude
(maximum)
30,000 ft @ 12C
Electrostatic
Discharge
External antennas: 12kV air, 6kV contact
Internal antennas: 15kV air, 8kV contact
MN000879A01B.fm Page 30 Thursday, July 10, 2014 11:01 AM