11. Cable the AP-7131 using either the Power Injector solution or an approved line cord and 
power supply.
For Motorola Power Injector installations:
a. Connect a RJ-45 CAT5e (or CAT6) Ethernet cable between the network data supply (host) 
and the Power Injector Data In connector.
b. Connect a RJ-45 CAT5e (or CAT6) Ethernet cable between the Power Injector Data & 
Power Out connector and the AP-7131 GE1/POE port. 
c. Ensure the cable length from the Ethernet source (host) to the Power Injector and 
AP-7131 does not exceed 100 meters (333 ft). The Power Injector has no On/Off power 
switch. The Power Injector receives power as soon as AC power is applied. For more 
information on using the Power Injector, see â
Power Injector Systemâ on page 7.
For standard power adapter (non Power Injector) and line cord installations:
a. Connect a RJ-45 CAT5e (or CAT6) Ethernet cable between the network data supply (host) 
and the AP-7131 GE1/POE or GE2 port.
b. Verify the power adapter is correctly rated according the country of operation.
c. Connect the power supply line cord to the power adapter.
d. Attach the power adapter cable into the power connector on the AP-7131.
e. Attach the power supply line cord to a power supply.
12. Verify the behavior of the AP-7131 LEDs. For more information, see â
LED Indicatorsâ on 
page 19.
13. The AP-7131 is ready to configure. For information on basic AP-7131 device configuration, 
see â
Configuring âBasicâ Device Settingsâ on page 24.
NOTE It is recommended the AP-7131 be mounted with the RJ45 cable 
connector oriented upwards or downwards to ensure proper operation.
CAUTION Do not actually connect to the power source until the cabling portion 
of the installation is complete.
!