Minitor IV    Pager Programming Guide 
 Getting Started 
 
Group Field Name  Description 
Stored Voice 
Function 
Enable or disable stored voice models with this 
option 
Fixed Alert  Select either ON or OFF. If ON is selected, the 
pager operates in the “fixed alert” mode. This 
means the tone alert is at maximum volume 
regardless of the position of the volume control. 
If OFF is selected, then the alert tone and voice 
audio level is adjustable using the volume 
control. 
Priority Scan F1  Select either ON or OFF. If the pager model is 
configured for scan option, then this field 
provides the ability to turn the PRIORITY 
feature ON or OFF. In the ON mode, the pager 
performs a priority scan function. In the OFF 
mode, the pager performs a normal scan with 
the priority feature omitted.  
Alert Duration  Select either standard (STD) or alert cycle 
duration variable (FIXED) in seconds. 
STD = Alert cycle controlled by the transmitted 
tone duration. 
FIXED = a fixed time entered by the user. 
Note: A message may be missed if the alert 
duration is too long. 
Call Reminder  When stored voice is present, this enables the 
pager to beep periodically indicating an unread 
message. 
Priority Alert  Select either ON or OFF. When ON Vibra-Page 
alerts are replaced by tone alert for call1 only. 
Privacy Select either ON or OFF. When set to ON, 
prevent the reset button from being used to 
monitor the channel. 
Reset Function 
(Automatic, 
Delayed N, Revert, 
Manual, Timeout, 
Revert N) 
Determines how a select call pager squelches a 
message after receiving a page. 
Model 
Option 
Squelch level 
(1 ~ 10) 
Select squelch level 
Note: Not all features are available on all models 
Table 5 Model Option Page 
 
 
6880309M81-A 9/20/2004  13