EasyManua.ls Logo

Motorola MTP8550Ex - Digital Duplex Test (Tx) Using IFR 3901;IFR 3902;IFR 3920; Digital Duplex Test (Tx) Using IFR 2968

Motorola MTP8550Ex
77 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.9
Digital Duplex Test (Tx) using IFR 3901/IFR 3902/IFR 3920
Procedure:
1 On the radio, press MenuContactContact 1Send.
The following results are displayed on the Tx Measurements window.
Burst Power Required Results: 28.0–32.0 dBm (Class 4) or 30.5–34.5 dBm
(Class 3L)
Power Profile: Passed
Burst Timing: ± 0.25 Symbols
Vector Error: Max 10% RMS, Max 30% Peak, Max 5% residual
Frequency Error: ± 100 Hz
2 Press Call MobileGroup CallTALKBACK.
3 Speak into the microphone of the handset.
You hear your speech (after a short delay) from the internal earpiece of the handset.
4 If you need more details, select
at the Rx Measurement Window.
Option Actions
Power Analyzer Graph
a Select PowerProfile Full.
b To view the detail of Profile Full, select and press
Select.
c To minimize the window, press Select.
d To view the rest of the power analyzer graphs, select
any item under Power drop-down list.
Vector Analyzer Diagram
a Select Mod AccuracyVector Error.
b To view the detail of Vector Error, select , and press
Select.
c To minimize the window, press Select.
d To view the rest of the vector analyzer graphs, select
any item under Mod Accuracy drop-down list.
5 Press End on the handset.
4.10
Digital Duplex Test (Tx) using IFR 2968
Procedure:
1 On the radio, press MenuContactContact 1Send.
The following results are displayed on IFR Manual Test Screen.
Burst Power Required Results: 28.0–32.0 dBm (Class 4) or 30.5–34.5 dBm
(Class 3L)
Power Profile: Passed
Burst Timing: ± 0.25 Symbols
Vector Error: Max 10% RMS, Max 30% Peak, Max 5% residual
Frequency Error: ± 100 Hz
MN002465A01-AN
Chapter 4 : Test Setup and Testing
42

Table of Contents

Other manuals for Motorola MTP8550Ex

Related product manuals