EasyManua.ls Logo

Mountz HDC-40i - User Manual

Mountz HDC-40i
89 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Feb 2016
Operation Manual
Hybrid Digital Screwdriver
HDC-40i, HDC-35i
1080 N 11th St San Jose CA 95112
www.mountztorque.com 408.292.2214
1

Questions and Answers

  • W
    William SchwartzAug 13, 2025
    What to do if there is a failure of air pressure in my Mountz Power Screwdriver?
    • M
      Martha GarciaAug 13, 2025
      If you are experiencing a failure of air pressure with your Mountz Power Screwdriver, first, turn off the power and check the air inlet outside. If the error persists after pressing the RESET button, check the air lines through the connector, cable, and actuator clutch.
  • S
    sullivankarenAug 16, 2025
    How to prevent overheat of motor in Mountz Power Screwdriver?
    • J
      Jonathan JacobsonAug 17, 2025
      If your Mountz Power Screwdriver motor overheats, one solution is to use intermittent operation, such as 1 second ON followed by 3 seconds OFF.
  • C
    Charles WardAug 20, 2025
    What to do if my Mountz HDC-40i Power Screwdriver has communication failure over 1 sec?
    • K
      Kevin BallardAug 20, 2025
      If your Mountz Power Screwdriver experiences a communication failure lasting over 1 second, check the cable connection between the driver and the controller.
  • Q
    qwilliamsAug 25, 2025
    What to do if there is over current on AMP board circuit in Mountz HDC-40i Power Screwdriver?
    • U
      ugomezAug 25, 2025
      If you encounter an over current on the AMP board circuit with your Mountz Power Screwdriver, check for any mechanical load failures and inspect the motor quality.
  • K
    Kimberly NelsonAug 27, 2025
    What to do if my Mountz HDC-40i shows a Hall sensor error?
    • J
      Jacqueline CisnerosAug 28, 2025
      If you are experiencing a Hall sensor error with your Mountz Power Screwdriver, check the cable quality and connectors. Also, inspect the wiring inside the driver.
  • J
    Joshua VaughnSep 1, 2025
    What to do if I get a driver data error on my Mountz HDC-40i Power Screwdriver?
    • D
      Donna JohnsonSep 1, 2025
      If you are getting a driver data error with your Mountz Power Screwdriver, ensure that the controller power is off when the driver is connected to the controller.
  • W
    William ChapmanSep 4, 2025
    What to do if my Mountz HDC-40i has an initial communication failure?
    • M
      Michael MccoySep 4, 2025
      If your Mountz Power Screwdriver experiences an initial communication failure, retry powering on the device after turning it off.
  • R
    Randall JohnsonSep 8, 2025
    What happens in case of over time of Motor Lock in Mountz Power Screwdriver?
    • M
      Matthew CalderonSep 8, 2025
      To prevent the motor from overheating, the Mountz Power Screwdriver will stop immediately after 1 second from the motor lock.

Summary

General Safety Rules

Screwdriver Specifications

Controller Specifications

Outlines the electrical and air pressure specifications for the HDC controller.

System Operation

Front Panel Overview

Describes the controller's front panel display, buttons, and connectors.

PC Program Settings

Guides on setting torque, speed, and angle using the PC program, Hi-Manager.

Front Panel Settings

Explains how to set torque, speed, and angle directly via the controller's front panel.

Error Code Reference

System Errors

Lists system-related error codes, their descriptions, and methods for resetting them.

USB Communication

RS-232 C Communication

Auto Fastening Data Output

PC Communication Software: Hi-Manager

Parameter Configuration via Hi-Manager

Guides on setting various parameters like fastening, controller, and screw count using the Hi-Manager interface.

Mountz HDC-40i Specifications

General IconGeneral
ModelHDC-40i
TypePower Screwdriver
Power SupplyElectric
Voltage24V
BrushlessYes
Accuracy± 3%
Drive Size1/4" Hex
Speed (RPM)1000

Related product manuals