Injection molding open loop - gravimetric mode
Actual production data:
Using the toggle button , you can switch between production settings and production data.
1. Set and actual output: Set.: Re-calculated output (% kg/h, gr/sec)
Act.: Actual additive output ((%, gr/s or kg/h)
actual additive output is only visible after the first automatic RPM adjustment.
2. Speed: Actual motor speed (RPM)
3. Hopper weight: Material weight in the hopper
4. Time: Set dosing time (sec), when working TIMER input mode.
The average dosing time (sec), when working in RELAY input mode.
5. Act. Time: Count down of the actual dosing time (sec)