OPERATION MANUAL
OFFICE PRO 10
READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT
INSTALLATION AND USAGE, AND READ ALL SAFEGUARDS.
NO POSTAGE
NECESSARY
IF MAILED
IN THE
UNITED STATES
     
FIRST-CLASS MAIL PERMIT NO. 8390 LONG BEACH, CA
BUSINESS REPLY MAIL
DENSO SALES CALIFORNIA, INC.
3900 VIA ORO AVENUE
LONG BEACH CA 90810-9969

Table of Contents

Other manuals for Movincool Office Pro 10

Questions and Answers

  • D
    Dean ColonJul 29, 2025
    How to unlock Movincool Office Pro 10 control board?
    • M
      Melanie StuartJul 30, 2025
      If your Movincool Air Conditioner isn't responding to the control board or buttons and no diagnostic code is shown, the unit may be in programming mode and locked out. To resolve this, press the RUN and SET buttons simultaneously.
  • A
    Ashley GarrettAug 3, 2025
    Why is my Movincool Air Conditioner not cooling enough?
    • T
      Tammy TaylorAug 3, 2025
      Insufficient cooling in your Movincool Air Conditioner can stem from several factors. First, ensure that the environmental conditions are within the design specifications by adjusting installation or operation conditions. Check and clean or replace the air filter if it's clogged, and also clean the fins if they are clogged. Adjust the set point temperature if it exceeds the room temperature. Other potential causes include a defective room temperature thermistor (replace it), an improperly ducted exhaust outlet (duct it properly), a leak in the refrigerant system (repair it), or a restriction in the refrigerant system (identify and remove it).
  • M
    Matthew MoranAug 7, 2025
    What to do if my Movincool Office Pro 10 is leaking water?
    • J
      Jennifer GreeneAug 7, 2025
      If your Movincool Air Conditioner is leaking water, several issues could be the cause. It could be that the condensate pump isn't working, in which case you should repair or replace it. Ensure the drain tank is installed. If the drain tank is cracked, replace it. Check for any obstructions in the drain pan hole and clear them. Finally, make sure the drain hose isn't kinked; if it is, un-kink it.
  • C
    cochrankyleAug 12, 2025
    How to fix a Movincool Office Pro 10 that won't turn on?
    • N
      Nicholas ArnoldAug 12, 2025
      If your Movincool Air Conditioner isn't operating, start by checking for power at the receptacle and terminal block. If the fan mode DIP switch is set to “Stop” and the current set point temperature exceeds the room temperature, check all wire connections. Also, if the fan mode DIP switch is set to “Stop” and the unit has a defective condensate pump, check the relay board fuse. Other potential issues include a defective drain tank switch (check the relay board fuse), a defective or incorrect relay board (check all wire connections), or a defective control board (check all wire connections).
  • A
    Andrea MyersAug 15, 2025
    Why does my Movincool Office Pro 10 have weak airflow?
    • A
      astevensonAug 16, 2025
      If you're experiencing insufficient airflow from your Movincool Air Conditioner, start by cleaning the filters, as clogged fins on the evaporator or condenser (due to running the unit without filters) can restrict airflow. Also, check the fan setting and adjust it if it's on “Low”. A defective fan motor could also be the culprit, requiring replacement. Lastly, ensure that the static pressure doesn't exceed design specifications and adjust it if necessary.
  • A
    allenmichaelAug 20, 2025
    Why is my Movincool Office Pro 10 Air Conditioner making noise and shaking?
    • C
      Christine BennettAug 20, 2025
      Abnormal noise or shaking in your Movincool Air Conditioner can be attributed to several factors. Check the compressor mounting nut and tighten it if it's loose. Inspect the rubber grommet on the compressor mounting bolt for deformation or wear and replace it if necessary. Internal interference with other components may also cause these issues, so adjust internal components to eliminate interference. Finally, a damaged or out-of-balance fan can lead to noise and shaking, requiring repair or replacement.
  • K
    Karen GreenAug 25, 2025
    What to do if Movincool Office Pro 10 starts then stops?
    • J
      John LoveAug 25, 2025
      If your Movincool Air Conditioner starts but stops immediately, the room temperature and antifreeze thermistor connectors might be reversed on the control board; correct the wiring connection. Alternatively, a defective fan motor or compressor motor could be the cause, requiring replacement. A defective relay board could also be the issue, and you should replace it.

Summary

Foreword

Definition of Terms

Defines WARNING, CAUTION, and NOTE terms used in the manual.

General Warnings & Cautions

Inventory

Installation

Choosing an Installation Site

Provides precautions for selecting a suitable location for the unit.

Moving the Unit

Instructions on how to safely move the unit using side handles and casters.

Plugging in the Unit

Guides on checking and connecting the power cord to the outlet.

Features

Operation

Control Panel Overview

Details the function of each button and indicator on the unit's control panel.

Operating in COOL Mode

Explains how to use the unit in COOL mode and turn it off.

Operating in Fan Only Mode

Explains how to use the unit in Fan Only mode and turn it off.

Changing from Fan Only Mode to COOL Mode

Instructions on switching from Fan Only mode to COOL mode.

Programming the Unit

Steps to set the current time and day for programming functions.

To Set a Program

Guides on selecting a program and setting the start day and time.

To Set a Program (Cont.)

Details on setting the stop time, temperature, and fan speed for programs.

To Set a Program (Cont.)

Instructions for changing fan speed and cycling between Cool/Fan modes in programs.

Program Control Flow

Explains program cycling options and how to cancel a running program.

Temperature Control

Explains how the thermistor controls automatic mode switching.

Fan Mode Control DIP Switch

Explains the DIP switch function for fan operation after compressor cycles off.

Temperature Scale Display DIP Switch

Explains the DIP switch for changing temperature display (°C vs °F).

Emptying the Drain Tank

Instructions for emptying the condensate drain tank and related warnings.

Installing the Condenser Plenum and Reducer

Guides on attaching the condenser plenum and reducer components.

Accessory Kit Components

Lists the components included in the window kit accessory.

Accessory Kit Installation

Instructions for attaching reducers to the window spacer and installing it.

Accessory Kit Duct Connection

Details on connecting ductwork to the reducer and unit, with warnings.

Remote Control Features

Explains the buttons and display functions of the optional remote control.

Optional Drain Pump Kit

Explains the function and operation of the optional drain pump kit.

Daily Inspection & Maintenance

Cleaning the Air Filters

Instructions on how to clean the air filters for optimal performance.

Filter Cleaning Method

Describes the method for cleaning the air filter elements.

Seasonal Maintenance

Outlines inspection and maintenance tasks for in-season and off-season periods.

Troubleshooting

Self-Diagnostic Codes

Lists error codes displayed on the control board and their meanings.

Technical Specifications

Limited Warranty

Movincool Office Pro 10 Specifications

General IconGeneral
Cooling Capacity10, 000 BTU/h
Power Supply115V/60Hz
RefrigerantR-410A
Exhaust Hose Diameter5 inches
Operating Temperature Range64°F to 95°F
Power Consumption (Cooling)1100 W
Noise Level (High)52 dBA
Hose Length5 ft