MGate MB3000 Modbus Gateway User Manual
29
Environmental Limits
Operating Temperature
0 to 60°C (32 to 140°F)
-
40 to 75°C (-40 to 167°F) for-T” models
Storage Temperature
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
5 to 95% (non-condensing)
Altitude
Up to 2000 m (795 hPa); higher altitudes on demand
Note: Please contact Moxa if you require products guaranteed to function properly at higher altitudes.
Standards and Certifications
Safety
EN 60950-1, IEC 60950-1, UL 62368-1, IEC 62368-1
Hazardous Location
UL/cUL Class 1 Division 2 Groups A/B/C/D,
ATEX Zone 2 Ex nA IIC T4 Gc
EMC
CE, FCC
EMI
EN 55032 Class A, FCC Part 15 Subpart B Class A
EMS
EN 55024,
EN 61000
-4-2 (ESD) Level 3,
EN 61000
-4-3 (RS) Level 3,
EN 61000
-4-4 (EFT) Level 4,
EN 61000
-4-5 (Surge) Level 3,
EN 61000
-4-6 (CS) Level 3,
EN 61000
-4-8 (PFMF) Level 1,
EN 61000
-4-11
Marine
DNV
Shock
IEC 60068-2-27
Freefall
IEC 60068-2-32
Vibration
IEC 60068-2-6
Reliability
MTBF (mean time between
failures)
MGate MB3170: 1,349,710 hrs.
Warranty
Period
5 years

Table of Contents

Other manuals for Moxa Technologies MGate MB3480

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Moxa Technologies MGate MB3480 and is the answer not in the manual?

Moxa Technologies MGate MB3480 Specifications

General IconGeneral
BrandMoxa Technologies
ModelMGate MB3480
CategoryGateway
LanguageEnglish

Related product manuals